Intertek Directory of Building Products

Dunbarton Rediflex® 20-90 Min Adjustable Steel Doorframe PP Company: Dunbarton Corporation

CATEGORY C - PROPRIETARY FRAMES

 

Roll Formed Steel Door Frame (18 gauge base) (Knock-Down) (Adjustable) for installation singly in 90 locations in steel/wood stud Drywall or Masonry Openings. Model No. Rediflex*.

 

Rating

Max. Size

Wall Construction

Min. Wall Thickness

Door Type

Remark

90 Min.

3'0" wide x 8'0" high

Minimum 90 minute Steel/Wood Stud Drywall or Masonry

4"

Listed

Hollow Metal Flush

Steel Trim

90 Min

3'6" wide x 7'0" high

Minimum 90 minute Steel/Wood Stud Drywall or Masonry

4"

Listed

Hollow Metal Flush

MDF or Steel Trim

 

Roll Formed Steel Door Frame (18 or 20 gauge base) (Knock-Down) (Adjustable) for installation singly or in pairs in 1 hour locations in steel/wood stud Drywall or Masonry Openings. Model No. Rediflex*.

 

Rating

Max. Size

Wall Construction

Min. Wall Thickness

Door Type

Remark

60 Min.

4'0" wide x 8'0" high
8'0" wide x 8'0" high

Minimum 60 minute Steel/Wood Stud Drywall or Masonry

4"

Listed

Steel Stiffened

Wood or Steel Casing

 

Roll Formed Steel Door Frame (18 or 20 gauge base) (Knock-Down) (Adjustable) for installation singly or in pairs in 20 to 45 minute locations in steel/wood stud drywall or masonry opening. Model Nos. Rediflex*.

 

Rating

Maximum Size

Wall Construction

Min. Wall Thickness

Door Type

Gasket System

20 Min.

4'0" wide x 8'0" high
8'0" wide x 8'0" high

Minimum 60 Minute

Wood/Steel Stud Drywall or Masonry

4"

Listed

Wood flush or simulated panel hardboard skin

Pemko HSS2000

45 Min.

4'0" wide x 9'0" high

Minimum 60 Minute

Fire Retardant Treated Wood/Steel Stud Drywall or Masonry

4"

Listed

Composite core wood door

Pemko HSS2000 and S88 or S44

 

Roll Formed Steel Door Frame (18 or 20 Gauge base) (Knock-Down) (Adjustable) for installation singly or in pairs in up to 45 minute locations in steel/wood stud drywall or masonry opening. Model Nos. Rediflex*.

 

Rating

Maximum Size

Wall Construction

Min. Wall Thickness

Door Type*

Edge-Seal System

20 Min.

4'0" wide x 8'0" high
8'0" wide x 8'0" high

Minimum

60 Minute

Wood/Steel
Stud drywall or Masonry

4"

Listed

Wood Flush or simulated panel

Pemko HSS2000

45 Min.

4'0" wide x 9'0" high

Minimum 60 Minute

Wood/Steel
Stud drywall or Masonry

4"

Listed

Composite core wood door

Pemko HSS2000 & S88/S44

 

Evaluated to the following...

This category includes frames not based on ANSI-A155.1/UL-63 construction Type (such as aluminum, wood, light gauge steel, composite, etc.). These listings will reference specific door types for which each frame is qualified. All frames listed in this section may be used in positive pressure assemblies per the terms and limitations of the individual listing.

 

All frames in this category are identified by a label or marking bearing the wording, "Listed Fire Door Frame", the Warnock Hersey Certification Mark, "UBC-7-2-97/UL-10C. Frames rated at less than 3 hours will have a time interval noted on the label/marking.

Listing Report Return to Search
Attributes
CriteriaCAN4 S104 (1985)
CriteriaNFPA 252 (2008)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min PP Category C Proprietary Frame
Fire Resistance45 Min PP Category C Proprietary Frame
Fire Resistance60 Min PP Category C Proprietary Frame
Fire Resistance90 Min PP Category C Proprietary Frame
Frame OptionsSteel 2 piece Adjustable
Listing SectionCATEGORY C - PROPRIETARY FRAMES
Spec ID25045