Intertek Directory of Building Products

Dunbarton Rediframe® 20-90 Minute Steel Fire Doorframe NP Company: Dunbarton Corporation

Roll Formed Steel Door Frame (20 or 22 gauge) (Knock-Down) for installation singly or in pairs up to and including 1-1/2 hour locations in steel/wood stud drywall or masonry openings.
Limitations: 4" x 4" Hinges 
 
Rating Max. Size
Openings
Maximum Overall
Dimensions
Min. Throat
Opening
Remark
90 Min. Singles: 3'0" wide x 9'0" high
Pairs: 6'0" wide x 9'0" high
Singles: 39" wide x 110" high
Pairs: 75" wide x 110" high
3-1/2" Steel
Casing
20-60 Min. Singles: 3'0" wide x 9'0" high
Pairs: 6'0" wide x 9'0" high
Singles: 39" wide x 110" high
Pairs: 75" wide x 110" high
3-1/2" Wood
Casing

Pressed Steel Door Frame (18, 16 gauge) (Knock-Down) for installation up to and including 1-1/2 hour locations in steel/wood stud drywall or masonry openings.
 
Maximum Size of Openings: Singles- 4'0" wide x 8'0" high
Pairs- 8'0" wide x 8'0" high
Maximum Overall Dimensions: Singles- 51-1/4" wide x 97-1/2" high
Pairs- 99-1/2" wide x 97-1/2" high
Minimum Throat Opening: 4-3/4"

Evaluated to the following...
Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN4-S104(ULC-S104), Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UL-10(b), Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.
Listing Report Return to Search
Attributes
CriteriaNFPA 80 (1999)
CriteriaASTM E152-81a
CriteriaUL 10(b) (1997)
CriteriaNFPA 252 (1999)
CriteriaCAN4 S106 (1985)
CriteriaCAN4 S104 (1985)
CriteriaUL 10(b) 2008 (R2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min NP Fire Doorframe
Fire Resistance45 Min NP Fire Doorframe
Fire Resistance60 Min NP Fire Doorframe
Fire Resistance90 Min NP Fire Doorframe
Listing SectionDOOR FRAMES
Spec ID25049
SwingSingle Swing
SwingStandard Pairs
Design Documents
No Results
Public Documents
No Results