Garland Combustible Deck (AC-01) Company: Garland Company, Inc. (The)

Combustible Deck (AC-1)
Slope:
3:12

  1. Gypsum board underlayment, mechanically fastened.
  2. *"GRA" EPDM membrane, fully adhered with "Garlastic" or "Garlastic KM", hot mopped, with all seams 4" lapped, sealed, and over poured with same.
  3. One layer 4 mil polyethylene separator sheet, loose laid.
  4. Dow "Styrofoam" RM or TG extruded polystyrene insulation, loose laid.
  5. One layer scrim separator sheet, "Fabrene" or "Rulon" polyolefin, 2 oz./sq. yd.
  6. Surfaced with nominal 3/4" to 1-3/4" round stone roofing ballast at a minimum coverage rate of 900 lbs./sq. to cover.

Note: The component materials of each system must be applied in the order in which they are listed above.

 

Evaluated to the following

The roof covering systems in this section have been evaluated for external fire resistance Classifications A, B, C as outlined by the following test methods:

ASTM-E108 - American Society for Testing & Materials 'Standard Methods of Fire Test of Roof Covering'
FM-4470, Section 5.1.A - Factory Mutual 'Standard Method of Test for Fire Resistance of Roof Covering Materials'
NFPA-256 - National Fire Protection 'Standard Method of Fire Tests of Roof Covering'
UBC-15-2-94 - Uniform Building Code 'Test Standard for Determining the Fire Retardancy of Roof Covering Materials'
ULC-S107 - Underwriters' Laboratories of Canada 'Standard Method of Tests for Fire Resistance of Roof Covering Materials'
UL-790 - Underwriters' Laboratories Inc. 'Tests for Fire Resistance of Roof Covering Materials'

Each system listing identifies the deck substrate as either non-combustible or combustible. Systems evaluated for combustible decks will provide the same ratings when applied over non-combustible decks.Unless otherwise noted in individual listings, combustible decks shall be sheathed with a minimum 15/32" veneer plywood or minimum 7/16" non-veneer APA rated sheathing panel (oriented strand board panels, structural particleboard panels, composite panels or wafer-board panels) or 3/4" thick solid wood sheathing boards. The component materials of each system must be applied in the order in which they are listed. All components of the system must be listed for external fire exposure by an agency acceptable to the AHJ.

Some Roof Covering Systems have been evaluated for other performance characteristics, in addition to external fire exposure. Where applicable, such additional performance characteristics are noted within the specific listing.

In all cases, manufacturer's instructions should be consulted for installation procedures and details not covered by these listings.

Listed Materials are identified by a label or marking bearing the wording, "Listed Roofing Component", a reference number or code and the WHI Certification Mark.

Listing Report Return to Search
Attributes
CriteriaUBC 15-2 (1994)
CriteriaASTM E108 (2000)
CriteriaNFPA 256 (2003)
CriteriaCAN / ULC S107 (1987)
CriteriaFM 4470 (1986) Section 5.1.1
CriteriaUL 790 (2004)
CSI Code07 30 00 Steep Slope Roofing
Listing SectionROOF COVERING SYSTEMS
Roofing: Deck TypeCombustible
Roofing: Fire RatingClass A
Roofing: Maximum Slope3:12
Spec ID10461