SAFTI FIRST 3 Hour Steel Flush Fire Door (C-Channel) – PP/NP Company: SAFTI FIRST

Specifications
Door Size Door Thickness Core Thickness Stiffeners
Single Swing:                                           4'0"wide x 7'2"high1  Minimum 1-3/4" ± 1/16" Minimum 1-1/2" 18 GA Steel C-Channel
Pairs:                                                      8'0"wide x 7'2"high1 Minimum 1-3/4" ± 1/16" Minimum 1-1/2" 18 GA Steel C-Channel
Double Egress:                                         Not Allowed. Not Applicable. Not Applicable. Not Applicable.

[1] Maximum height increases to 10'0" for doors rated up to 90 minutes.  Minimum 3 point latching for std. pairs.

Vision Panel:

Rating

Max Area (Visible)

Max Height (Visible)

Max Width (Visible)

20/45 Minute

1296 sq. in.

54"

30"

60/90 Minute

100 sq. in.

33"

10"

Listing Report Return to Search
Attributes
CriteriaUL 10(c) (1998)
CriteriaUBC 7-2 (1997)
CriteriaNFPA 252 (1999)
CriteriaASTM E2074 (2000)
CriteriaCAN4 S104 (1985)
CriteriaASTM E2074 (2004)
CriteriaNFPA 252 (2008)
CriteriaUL 10(c) (2009)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance45 Min Neutral Pressure
Fire Resistance90 Min Neutral Pressure
Fire Resistance2 Hour Neutral Pressure
Fire Resistance3 Hour Neutral Pressure
Fire Resistance60 Min Neutral Pressure
Fire Resistance2 Hour Positive Pressure
Fire Resistance45 Min Positive Pressure
Fire Resistance90 Min Positive Pressure
Fire Resistance60 Min Positive Pressure
Fire Resistance3 Hour Positive Pressure
Fire Resistance20 Min Neutral Pressure
Fire Resistance20 Min Positive Pressure
Listing SectionDOORS
Spec ID15094