Smoke-Control and Fire-Rated Access Door/Frame Assembly (16 gauge) (Cold-Rolled or Stainless Steel) (Insulated) (Latch-Operated) for installation in Horizontal Floor/Ceiling Assemblies.
Maximum Size of Openings: |
Horizontal Installation: 24" wide x 36" high Vertical Installation: 32" wide x 32" high (Single Latch) 48" wide x 50" high (Double Latch) |
Ratings: |
1 Hour: Wood Framed Assemblies 3 Hour: Non-Combustible Assemblies |
Testing Standard: UBC 43-7.
Evaluated to the following:
All assemblies in this section are identified by a label or marking bearing the wording "Listed (Product)", a time interval, a serial number and the Warnock Hersey Certification Mark and are installed in accordance with the following:
NFPA-80, Fire Doors & Windows, or
National Building Code of Canada, and
Manufacturer's Instructions.