FIRE WINDOW FRAMES
Pressed Steel Fire Window Frame (14, 16 gauge) (welded-up) (Fixed Section or Adjustable Split Section) for installation in 3/4 hour locations, in steel/wood stud drywall or masonry openings.
Limitations: Firelite or Firelite Plus glazing may be provided with a maximum rating of 3/4 hour, with 5/8" high glass stops.
|
Maximum Size Light: (Fixed) |
3,325 sq.in. (Clear View) |
|
Maximum Clearview Width |
95" |
|
Maximum Clearview Height |
54" |
|
Maximum Size of Lengths |
1,296 - Listed Wire Glass |
|
Minimum Wall Thickness: |
3-1/2" |
|
Maximum Overall: |
10'0" Wide x 7'4" High |
Evaluated to the following:
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E163, Methods of Fire Tests of Fire Window Assemblies.
CAN/ULC-S106, Standard Method for Fire Tests of Window & Glass Block Assemblies.
NFPA-257, Standard Method for Fire Tests of Fire Window Assemblies.
UBC-7-4-94, Uniform Building Code.
UL-9, Fire Tests of Window Assemblies.
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All assemblies are identified by a label or marking bearing the wording "Listed Fire Window Frame", a time interval, a serial number and the WHI Certification Mark.