Intertek Directory of Building Products

Stiles 20 min to 3 hour Steel Double Egress Door Frame Company: Stiles Custom Metal, Inc.

Pressed Steel Cased Opening Door Frame with applied stops or Single Rabbet Frames (12, 14 or 16 gauge) (Welded Up) for installation singly or in pairs, including double egress pairs in up to 3 hour locations in masonry openings and 90 minutes in steel/wood stud drywall openings.
LIMITATIONS
Horton 4000 through 7000 Series Closer/Automatic Operator.
Besam SW200i Swing Door operator.  
Doors must be labeled Positive Pressure Fire Rated Doors.
Minimum Wall Thickness: 5-3/8".  
Rating Maximum Size* Wall Construction Door Type
20 Minute 8'0" wide x 8'0" high Masonry & Drywall Wood & Hollow Metal
45 to 90 Minute 8'0" wide x 8'0" high Masonry & Drywall Wood Composite & Hollow Metal
3 Hour 8'0" wide x 8'0" high Masonry Hollow Metal
*Maximum Height of 10'0" is permitted if the following conditions are satisfied:
  • Frames used in 90 to 180 minute applications are fully grouted
  • Minimum 2" face and 5/8" high stops
  • Anchors per UL Subject 63 and hinges per NFPA 80
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016) Ed. 3 (R:27 May 2021)
CriteriaNFPA 252 (2022)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min PP Category C Proprietary Frame
Fire Resistance45 Min PP Category C Proprietary Frame
Fire Resistance3 Hour PP Category C Proprietary Frame
Fire Resistance60 Min PP Category C Proprietary Frame
Fire Resistance90 Min PP Category C Proprietary Frame
Listing SectionCATEGORY C - PROPRIETARY FRAMES
Spec ID16952
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
Design Documents
No Results
Public Documents