Intertek Directory of Building Products

Chem-Pruf High Velocity Storm Door Flush Design F and Embossed Design E Company: Chem-Pruf Door Company

WIND LOAD RESISTANT DOORS

*"High Velocity Storm Door - Flush Design F and Embossed Design E" Including Attached Frame, In-Swing and Out-Swing, Flush or Embossed Door, for installation in single swing locations, rated at ± 70 psf and Impact Missile Level D (350 ft./lb.).

Maximum Nominal Size of Opening: Single Swing: 3'0" wide x 7'0" high

*Manufacturing Designation.
Additional Standards: ASTM-E1886, ASTM-E1996.

Evaluated to the following:

Unless otherwise noted, assemblies in this section have been tested in accordance with the following standard: ASTM-E330, "Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference" and are installed according to the manufacturer's installation instructions and identified with the WHI Certification Mark.

Listing Report Return to Search
Attributes
CriteriaASTM E1886 (2005)
CriteriaASTM E1996 (2008)
CSI Code08 30 00 Specialty Doors and Frames
DP Rating (psf)70
Impact Missile LevelLevel D
Listing SectionWIND LOAD RESISTANT DOORS
Spec ID17480
SwingSingle Swing
Windload/StructuralASTM E1886 Hurricane Impact
Windload/StructuralASTM E330-2002 Windload
Windload/StructuralASTM E1996 Hurricane Impact Levels
Design Documents
No Results
Public Documents
No Results