Garland Non-Combustible Deck (AN-17) Company: Garland Company, Inc. (The)

Non-Comb. Deck (AN-17)
Slope: 1/4:12

    1. Optional Insulation: Wood fiber, Glass fiber, polyisocyanurate, perlite, any thickness or combination of these or 1/2" Dens Deck, 1/2" perlite or 1/2" wood fiberboard applied over EPS insulation. Note: When EPS insulation is applied over a metal or combustible deck, a thermal barrier complying with section 2603.4.1.5 of the IBC is required.

    2. Optional: Minimum two plies of ASTM-D2178 Type IV or VI asphalt felts or HPR Polyscrim, or HPR Polyscrim Plus in ASTM-D312 roofing asphalt, HPR All-Temp or Garlastic.

    3. Cap Sheet: One ply of Garland Modified Bitumen cap sheet VersiPly 40, 60, 80, StressPly, StressPly FR, StressPly E, StressPly E FR, StressPly EUV, StressPly EUV FR, Stress-Ply Plus, StressPly Plus FR in ASTM-D312 roofing asphalt, HPR All-Temp or Garlastic.

    4. Surfaced with roofing gravel ballast applied at a coverage rate of 400 lbs./sq. (minimum) into a flood coat of either ASTM-D312 roofing asphalt, HPR All-Temp or Garlastic, WeatherScreen, ASTM-D450 coal tar, Black Knight, Black Knight LV, Black Knight Cold or Black Knight WB.

Note: The component materials of each system must be applied in the order in which they are listed above. 

 

Evaluated to the following:

The roof covering systems in this section have been evaluated for external fire resistance Classifications A, B, C as outlined by the following test methods:

ASTM-E108 - American Society for Testing & Materials 'Standard Methods of Fire Test of Roof Covering'

FM-4470, Section 5.1.A - Factory Mutual 'Standard Method of Test for Fire Resistance of Roof Covering Materials'

NFPA-256 - National Fire Protection 'Standard Method of Fire Tests of Roof Covering'

UBC-15-2-94 - Uniform Building Code 'Test Standard for Determining the Fire Retardancy of Roof Covering Materials'

ULC-S107 - Underwriters' Laboratories of Canada 'Standard Method of Tests for Fire Resistance of Roof Covering Materials'

UL-790 - Underwriters' Laboratories Inc. 'Tests for Fire Resistance of Roof Covering Materials'

Each system listing identifies the deck substrate as either non-combustible or combustible. Systems evaluated for combustible decks will provide the same ratings when applied over non-combustible decks.Unless otherwise noted in individual listings, combustible decks shall be sheathed with a minimum 15/32" veneer plywood or minimum 7/16" non-veneer APA rated sheathing panel (oriented strand board panels, structural particleboard panels, composite panels or wafer-board panels) or 3/4" thick solid wood sheathing boards. The component materials of each system must be applied in the order in which they are listed. All components of the system must be listed for external fire exposure by an agency acceptable to the AHJ.

Some Roof Covering Systems have been evaluated for other performance characteristics, in addition to external fire exposure. Where applicable, such additional performance characteristics are noted within the specific listing.

In all cases, manufacturer's instructions should be consulted for installation procedures and details not covered by these listings.

Listed Materials are identified by a label or marking bearing the wording, "Listed Roofing Component", a reference number or code and the WHI Certification Mark.

Listing Report Return to Search
Attributes
CriteriaUBC 15-2 (1994)
CriteriaNFPA 256 (2003)
CriteriaFM 4470 (1986) Section 5.1.1
CriteriaUL 790 (2004)
CriteriaASTM E108 (2004)
CSI Code07 30 00 Steep Slope Roofing
Listing SectionROOF COVERING SYSTEMS
Roofing: Deck TypeNon-Combustible
Roofing: Fire RatingClass A
Roofing: Maximum Slope1/4:12
Spec ID17545