Non-Comb. Deck (AN-22)
Slope: 1/4:12
1. Optional Insulation's: Wood Fiber, glass fiber, polyisocyanurate, perlite, any thickness or combinations of these or 1/2" Dens Deck, 1/2" perlite or 1/2" wood fiberboard applied over EPS insulation. Note: When EPS insulation is applied over a metal or combustible deck, a thermal barrier complying with section 2603.4.1.5 of the IBC is required.
2. Optional: Minimum two plies of ASTM-D2178 Type IV or VI asphalt felts or HPR Polyscrim or HPR Polyscrim Plus in hot asphalt.
3. Cap Sheet: One ply of Garland modified bitumen cap sheet (StressPly, StressPly Plus, StressPly E, VersiPly 40 VersiPly 60 or VersiPly 80) in hot asphalt.
4. Surfaced with roofing gravel ballast applied at a coverage rate of 400 lbs./sq. (minimum) into a flood coat of either ASTM-D312 asphalt, ASTM-D540 coal tar, Black Knight, Black Knight LV, Black Knight Cold or Black Knight WB.
Note: The component materials of each system must be applied in the order in which they are listed above.
Evaluated to the following:
The roof covering systems in this section have been evaluated for external fire resistance Classifications A, B, C as outlined by the following test methods:
ASTM-E108 - American Society for Testing & Materials 'Standard Methods of Fire Test of Roof Covering'
FM-4470, Section 5.1.A - Factory Mutual 'Standard Method of Test for Fire Resistance of Roof Covering Materials'
NFPA-256 - National Fire Protection 'Standard Method of Fire Tests of Roof Covering'
UBC-15-2-94 - Uniform Building Code 'Test Standard for Determining the Fire Retardancy of Roof Covering Materials'
ULC-S107 - Underwriters' Laboratories of Canada 'Standard Method of Tests for Fire Resistance of Roof Covering Materials'
UL-790 - Underwriters' Laboratories Inc. 'Tests for Fire Resistance of Roof Covering Materials'
Each system listing identifies the deck substrate as either non-combustible or combustible. Systems evaluated for combustible decks will provide the same ratings when applied over non-combustible decks.Unless otherwise noted in individual listings, combustible decks shall be sheathed with a minimum 15/32" veneer plywood or minimum 7/16" non-veneer APA rated sheathing panel (oriented strand board panels, structural particleboard panels, composite panels or wafer-board panels) or 3/4" thick solid wood sheathing boards. The component materials of each system must be applied in the order in which they are listed. All components of the system must be listed for external fire exposure by an agency acceptable to the AHJ.
Some Roof Covering Systems have been evaluated for other performance characteristics, in addition to external fire exposure. Where applicable, such additional performance characteristics are noted within the specific listing.
In all cases, manufacturer's instructions should be consulted for installation procedures and details not covered by these listings.
Listed Materials are identified by a label or marking bearing the wording, "Listed Roofing Component", a reference number or code and the WHI Certification Mark.