Intertek Directory of Building Products

Titan Metal 45 Min Fire Window Assembly Company: Titan Metal Products, Inc.

Pressed Steel Fire Window Frame (14, 16 gauge) (Welded Up) (Fixed Section or Adjustable Split Sections) for installation in 3/4 hour locations in steel/wood stud drywall or masonry openings.

Maximum Size of Light: 2,550 sq.in.
Maximum Overall Dimensions: 9'4" wide x 8'10" high
Minimum Wall Thickness: 3-3/4"


Evaluated to the following:

Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E163, Methods of Fire Tests of Fire Window Assemblies.
CAN/ULC-S106, Standard Method for Fire Tests of Window & Glass Block Assemblies.
NFPA-257, Standard Method for Fire Tests of Fire Window Assemblies.
UBC-7-4-94, Uniform Building Code.
UL-9, Fire Tests of Window Assemblies.
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.

Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All assemblies are identified by a label or marking bearing the wording "Listed Fire Window Frame", a time interval, a serial number and the WHI Certification Mark.

Listing Report Return to Search
Attributes
CriteriaASTM E163 (1984)
CriteriaNFPA 257 (2000)
CriteriaUL 9 (2000)
CriteriaUBC 7-4 (1994)
CSI Code08 11 00 Metal Doors and Frames
Listing SectionFIRE WINDOW FRAMES
Spec ID19124
Design Documents
No Results
Public Documents
No Results