Intertek Directory of Building Products

MM Systems Pyro-Flex® PF-3118F-SC Series Company: MM Systems OPCO LLC

MM Systems Pyro-Flex® PF-3118F-SC Series (formerly Pyro-Flex® PF-3100F Series)

These asymmetrical expansion joint assemblies consist of various designs made up of two parts. The fire-resistive Pyro-Flex® portion consists of flexible ceramic fiber blanket of varying sizes and thicknesses; and the architectural joint system portion, also called an architectural cover plate, which is elastomeric or metallic, and is able to slide open and close. These fire-resistive joint systems are recognized for use in horizontal assemblies, as well as at the junction or connection point. The horizontal Pyro-Flex® consists of a fire blanket system, which spans to each face of the floor assembly, forming a protection from the underside of the floor assembly.

RATINGS 

 

Standard

Rating

Design Number

Former OPL Design Number

ASTM E 1966

3 hour

MM/EJH 180-01

CEJ 517 F

ANSI/UL 2079

3 hour

MM/EJH 180-01

CEJ 517 F

 

Standard

L-Rating

Design Number

Former OPL Design Number

ANSI/UL 2079

0 SCFM/LF

MM/EJH 180-01

CEJ 517 F

 

Standard

Cycling

Design Number

Former OPL Design Number

ASTM 1399, ASTM E 1966, & ANSI/UL 2079

Class IV,

+/- 50% movement

MM/EJH 180-01

CEJ 517 F

 

For Cycling, summary of movement capability, M, as related to maximum joint width, Wmax, and minimum joint width, Wmin.

 

Model Number

Wmax

(inches)

Wmin

(inches)

M

(inches)

PF-3118F-SC 1-1

2

0.875

1.125

PF-3118F-SC 2-1

3

1

2

PF-3118F-SC 2-2

4

2

2

PF-3118F-SC 3-1.5

4.5

1.5

3

PF-3118F-SC 3-3

6

3

3

PF-3118F-SC 4-2

6

2

4

PF-3118F-SC 4-4

8

4

4

PF-3118F-SC 5-2.5

7.5

2.5

5

PF-3118F-SC 5-5

10

5

5

PF-3118F-SC 6-3

9

3

6

PF-3118F-SC 6-6

12

6

6

PF-3118F-SC 7-3.5

10.5

3.5

7

PF-3118F-SC 7-7

14

7

7

PF-3118F-SC 8-4

12

4

8

PF-3118F-SC 8-8

16

8

8

PF-3118F-SC 9-4.5

13.5

4.5

9

PF-3118F-SC 9-9

18

9

9

PF-3118F-SC 10-5

15

5

10

PF-3118F-SC 11-5.5

16.5

5.5

11

PF-3118F-SC 12-6

18

6

12

Listing Report Return to Search
Attributes
CriteriaANSI / UL 2079 (1998)
CriteriaASTM E1966 (2001)
CriteriaASTM E1399 Cycling
CriteriaASTM E1966 (2007)
CSI Code07 95 00 Expansion Control
Fire Resistance3 Hour Fire Rated
Listing SectionEXPANSION/SEISMIC JOINTS
Spec ID19606
Design Documents
Public Documents