OC - Titanium Roofing Underlayments Company: Owens Corning Roofing and Asphalt, LLC Code Compliance Research Reports: CCRR-1024

Titanium® FR self-adhered roofing underlayment is comprised of seven bonded layers. The sequence of layers from the exposed side to the sheating side is non-woven scrim, Fire-Rated coating, fiberglass mesh, Fire-Rated coating, High-Density Polyethylene (HDPE) film, adhesive coating, and HDPE release film. The underlayment weighs 51.3 pounds per 100 square feet and is available in rolls 36 inches wide by 56 feet long. 

Titanium® PSU 30 self-adhered roofing underlayment is comprised of an un-reinforced polymer modified bitumen material adhered to the underside of a polymer coated, synthetic woven material. The underside of the membrane (bitumen material) is backed with a release film that is removed prior to application of the membranes to the roof deck. The top surface of the membrane is grey in color.  The underlayment weighs 26.5 pounds per 100 square feet and is available in rolls 36 inch wide by 72 feet long rolls.
 
PHYSICAL RATINGS
PRODUCT TEST METHOD TEST PROCEDURE RESULTS
TITANIUM® FR and PSU 30 ASTM D1970 Physical Properties  Meets the requirements 
 
FIRE CLASSIFICATION
Class A Assemblies
Assembly No. E108-RFU-19682-02
Slope:
Deck Type:
Details:
2:12 or greater
Combustible
  • Minimum nominal 3/8” thick Code Compliant exterior grade plywood
  • A single layer of TITANIUM® PSU 30 adhered to the deck
  • Asphalt shingles Listed per ASTM D3462 with a minimum weight of 190 pounds per 100 square feet installed per manufacturer’s installation instruction
Assembly No. E108-RFU-19682-03
Slope:
Deck Type:
Details:
  • Slope: 2:12 or greater
  • Deck: Minimum 15/32 in. thick code compliant exterior grade plywood
  • Single layer of Titanium FR underlayment adhered to the deck in accordance with manufacturer’s installation instructions.
  • Roof covering: ASTM C1167 compliant clay roof tile (minimum 6.98 lb/ft2) installed in accordance with the roof tile manufacturer’s installation instructions. The roof covering must be recognized in a Listing Report for Class A Spread of Flame per ASTM E108 requirements.
Assembly No. E108-RFU-19682-04
Slope:
Deck Type:
Details:
  • Slope: 2:12 or greater
  • Deck: Minimum 15/32 in. thick code compliant exterior grade plywood
  • Single layer of Titanium FR underlayment adhered to the deck in accordance with manufacturer’s installation instructions.
  • Roof covering: ASTM C1492 compliant concrete roof tile (minimum 12.2 lb/ft2) installed in accordance with the roof tile manufacturer’s installation instructions. The roof covering must be recognized in a Listing Report for Class A Spread of Flame per ASTM E108 requirements.
Assembly No. E108-RFU-19682-05
Slope:
Deck Type:
Details:
  • Slope: 2:12 or greater
  • Deck: Minimum 15/32 in. thick code compliant exterior grade plywood
  • Single layer of Titanium FR underlayment adhered to the deck in accordance with the manufacturer’s installation instructions.
  • Roof covering: Minimum 26-gauge steel roof panels installed in accordance with the roof panel manufacturer’s installation instructions. The roof covering must be recognized in a Listing Report for Class A Spread of Flame per ASTM E108 requirements.
Assembly No. E108-RFU-19682-06
Slope:
Deck Type:
Details:
  • Slope: 2:12 or greater
  • Deck: Minimum 15/32 in. thick code compliant exterior grade plywood
  • Two layers of Titanium FR underlayment adhered to the deck in accordance with the manufacturer’s installation instructions.
  • Roof covering: Minimum 0.032 in. aluminum roof panels installed in accordance with the roof panel manufacturer’s installation instructions. The roof covering must be recognized in a Listing Report for Class A Spread of Flame per ASTM E108 requirements.
Assembly No. E108-RFU-19682-07
Slope:
Deck Type:
Details:
  • Slope: 2:12 or greater
  • Deck: Minimum 3/8 in. thick Code Compliant exterior grade plywood. 
  • Single layer of Titanium FR underlayment adhered to the deck in accordance with manufacturer’s installation instructions.
  • Roof covering: ASTM D3462 compliant asphalt shingles installed in accordance with manufacturer’s installation instructions.
  • Rack-mounted PV panel or modules: UL 1703 compliant (Class A, B, or C) PV panels or modules installed over the asphalt shingles in accordance with manufacturer's installation instructions. 
Assembly No.     E108-RFU-19682-08
Slope:
Deck Type:
Details: 
  • Slope: 2:12 or greater 
  • Deck: Minimum 15/32 in. thick Code Compliant exterior grade plywood 
  • Single layer of Titanium FR underlayment adhered to the deck in accordance with the manufacturer's installation instructions. 
  • Roof Covering: Minimum 26-guage steel stone-coated shingles installed in accordance with the roof shingle manufacturer's installation instructions. The roof covering must be recognized in a Listing Report for Class A Spread of Flame per ASTM E108 requirements. 
Assembly No. E108-RFU-19682-09
Slope:
Deck Type:
Details:
  • Slope: 2:12 or greater
  • Deck: Minimum 3/8 in. thick Code Compliant exterior grade plywood. 
  • Single layer of Titanium PSU 30 underlayment adhered to the deck in accordance with manufacturer’s installation instructions.
  • Roof covering: ASTM D3462 compliant asphalt shingles installed in accordance with manufacturer’s installation instructions.
  • Rack-mounted PV panel or modules: UL 1703 compliant (Class A, B, or C) PV panels or modules installed over the asphalt shingles in accordance with manufacturer's installation instructions

Class C Assemblies 
Assembly No. E108-RFU-19682-10
Slope:
Deck Type:
Details:
  • Slope: 2:12 or greater
  • Deck: Minimum 15/32 in. thick code compliant exterior grade plywood
  • One layer of Titanium PSU 30 underlayment adhered to the deck in accordance with the manufacturer’s installation instructions.
  • Roof covering: Minimum 0.032 in. aluminum roof panels installed in accordance with the roof panel manufacturer’s installation instructions. The roof covering must be recognized in a Listing Report for minimum Class C Fire Classification per ASTM E108.
Assembly No. E108-RFU-19682-11
Slope:
Deck Type:
Details:
  • Slope: 2:12 or greater
  • Deck: Minimum 15/32 in. thick code compliant exterior grade plywood
  • One layer of Titanium PSU 30 underlayment adhered to the deck in accordance with the manufacturer’s installation instructions.
  • Roof covering: Minimum 26-gauge steel roof panels installed in accordance with the roof panel manufacturer’s installation instructions. The roof covering must be recognized in a Listing Report for minimum Class C Fire Classification per ASTM E108.

CODE COMPLIANCE RESEARCH REPORT
Evaluation Method Building Code CCRR Number
ICC-ES AC188
ASTM D8257
2024, 2021, 2018 IBC and IRC CCRR-1024
 
FLORIDA PODUCT APPROVAL
Product Product Approval No.
Titanium PSU 30 Roofing Underlayment FL No. 11602
Listing Report Return to Search
Attributes
CriteriaASTM E108 (2007)
CriteriaCAN / CSA A220 Series-06 (2006)
CriteriaASTM E108 (2017)
CriteriaICC-ES AC188 (2015)
CriteriaASTM D1970 (2017)
CriteriaASTM D8257/D8257M (2020)
CriteriaUL 790 (2004) Ed. 8 (R2018)
CSI Code07 50 00 Membrane Roofing
Listing SectionROOFING MATERIALS