Intertek Directory of Building Products

ABS Ovation and Encore 20 Min (with hose) Fire Door MDF Panel Type PP Company: American Building Supply, Inc.

Medium Density Fiberboard (MDF) with Insert Raised or Flat Panel, or Routed Simulated Panel, Swinging-Type Fire Door for installation singly or in pairs in up to 20 minute locations with hose stream. For use in any "Category C - Standard" Frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions. Field-Applied Edge Seal System is required. Refer to the door manufacturer's installation instructions for Edge-Seal System requirements.
 
Limitations: Cylindrical and Mortise Latches with Maximum 2-3/4" Backset and Minimum 1/2" Bolt Throw for single swing door and 3/4" Bolt Throw for Pairs/Surface-Mounted Vertical Rod, Rim or Mortise Type Fire Exit Hardware or Manual Flush Bolts/Surface Bolts/Surface-Mounted Closer or Concealed Overhead Closer.  Door may be constructed with a square or arched top.
 
 
 
Configuration Maximum Size*
Single 4' 0" wide x 8' 0" high
Pair 8' 0" wide x 8' 0" high
Double Egress NA
Pairs require 3-Point Latching. 
Configuration Maximum Size*
Single 4' 0" wide x 8' 0" high
Pair 8' 0" wide x 8' 0" high
Double Egress NA
*See manufacturer's installation instructions for additional information, restrictions and limitations.
Testing Standards: UL-10C (Positive Pressure). 
 
Evaluated to the following...
 
This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.
 
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
 
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
 
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
 
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UL-10C & CAN/ULC S104".
 
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016) Ed. 3 (R:27 May 2021)
CriteriaNFPA 252 (2022)
CSI Code08 10 00 Doors and Frames
CSI Code08 14 00 Wood Doors
Fire Resistance20 Min w/Hose Stream PP Cat A Door
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID21118
SwingSingle Swing
SwingStandard Pairs
Design Documents
No Results
Public Documents