Horton Automatics Profiler ICU Smoke Rated Manual Sliding Door Systems Company: Horton Automatics, Division of Overhead Door Corporation

ProfilerICU™ Smoke Rated Door Systems are doors made of extruded aluminum framing, glazed with standard tempered glass.  All sliding door systems are combined into one category under the name of Profiler ICU Smoke Rated Manual Sliding Door Systems. The door systems that are in the category are as follows:
 
Profiler ICU Smoke Rated Manual Sliding Door System 
Series 2000 Type 310 (SO-SX)
 
Series 2000 Type 310 (SO-SX) Trackless
 
Series 2000 Type 010 (P-X / X-P)

ICU Series Type 010 (O-X/X-O)

ICU 90 degree Sidelite Series (SO-X-O-O/O-O-X-SO)
 
Profiler ICU Self Closing Manual Sliding Door
 
Profiler ICU Series 310 with Miniblinds and PLAM Smoke Rated Manual Sliding Door System

Smoke Rated Telescoping ICU/CCU Manual Door System
 
Series 2000B Isolation Door System (IDS)
 
Series 2000 (P-SX)

Profiler ICU Max Telescoping Trackless 310T

Profiler ICU Telescoping XM

Proslide Telescoping 2003T-IDS Series


Proslide Series 2021 Belt Drive Type 110 Single Slide O-SX or SX-O

Proslide Series 2021 Belt Drive Type 310 Single Slide SO-SX or SX-SO

FlexBarn Series Surface-Mounted Slide Door and Frame System Type 010T (X-OR, OL-X)

(Excluding Proslide Series 2021, optional glazing Vision Control Mini is approved for systems in this listing with single-sided control knob)
 
RATINGS

The following Profiler ICU Smoke Rated Manual Sliding Door Systems had a leakage rate not exceeding 3.0 CFM/sqft of door opening area at up to 0.3 inches water column at ambient temperature and at 400 deg F when tested to UL 1784, Standard for Safety Air Leakage Tests of Door Assemblies (2001) with artificial bottom seal.
  • Series 2000 Type 310 (SO-SX)
  • Series 2000 Type 310 (SO-SX) Trackless
  • Series 2000 Type 010 (P-X / X-P)
  • ICU 90 degree Sidelite Series
  • Profiler ICU Self Closing Manual Sliding Door
  • Profiler ICU Series 310 with Miniblinds and PLAM Smoke Rated Manual Sliding Door System
  • Series 2000B Isolation Door System (IDS)
  • Series 2000 (P-SX)
  • Profiler ICU Max Telescoping Trackless 310T
  • Profiler ICU Telescoping XM
  • Proslide Telescoping 2003T-IDS Series
  • Proslide Series 2021 Belt Drive Type 110 Single Slide O-SX or SX-O
  • Proslide Series 2021 Belt Drive Type 310 Single Slide SO-SX or SX-SO
  • FlexBarn Series Type 010 Biparting
  • FlexBarn Series Type 010 Single
The ICU Series Type 010 had a leakage rate not exceeding 3.0 CFM/sqft of door opening area at up to 0.3 inches water column at ambient temperature and at 400 deg F when tested to UL 1784, Standard for Safety Air Leakage Tests of Door Assemblies (2001) without artificial bottom seal.
Listing Report Return to Search
Attributes
Air Leakage2.73
CriteriaUL 1784 (2004)
CriteriaUL 1784 (2001)
CriteriaUL 1784 (2009)
CriteriaUL 1784 (2015)
CSI Code08 11 16 Aluminum Doors and Frames
Listing SectionSMOKE CONTROL DOOR ASSEMBLIES
Spec ID21706