Wood Core Type (Particle Board Core) Routed Simulated Panel, Swing-Type Fire Door for installation singly or in pairs in 20 minute locations (without hose). For use in any "Category C - Standard" Frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions. Field-Applied Edge Seal System is required. Refer to the door manufacturer's installation instructions for Edge-Seal System requirements.
Limitations: Cylindrical and Mortise Latches with Maximum 2-3/4" Backset and Minimum 1/2" Bolt Throw for single swing door and 3/4" Bolt Throw for Pairs/Surface-Mounted Vertical Rod, Rim or Mortise Type Fire Exit Hardware/Automatic or Manual Flush Bolts/Surface Bolts/Surface-Mounted Closer/Concealed Overhead Closer. Doors Pairs without Hose Stream may have 3 or 4-Point Latching.
Configuration
|
Maximum Size*
|
Single
|
4' 0" wide x 8' 0 " high
|
Pair
|
8' 0" wide x 8' 0" high
|
Double Egress
|
NA
|
*See manufacturer's installation instructions for additional information, restrictions and limitations.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).
Evaluated to the following...
This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.
These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C".