ABS Encore 20 Min (without hose) Routed Simulated Panel Fire Door PP Company: American Building Supply, Inc.

Wood Core Type (Particle Board Core) Routed Simulated Panel, Swing-Type Fire Door for installation singly or in pairs in 20 minute locations (without hose). For use in any "Category C - Standard" Frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions. Field-Applied Edge Seal System is required. Refer to the door manufacturer's installation instructions for Edge-Seal System requirements.

 

Limitations: Cylindrical and Mortise Latches with Maximum 2-3/4" Backset and Minimum 1/2" Bolt Throw for single swing door and 3/4" Bolt Throw for Pairs/Surface-Mounted Vertical Rod, Rim or Mortise Type Fire Exit Hardware/Automatic or Manual Flush Bolts/Surface Bolts/Surface-Mounted Closer/Concealed Overhead Closer. Doors Pairs without Hose Stream may have 3 or 4-Point Latching.

 

Configuration

Maximum Size*

Single

4' 0" wide x 8' 0 " high

Pair

8' 0" wide x 8' 0" high

Double Egress

NA

 

*See manufacturer's installation instructions for additional information, restrictions and limitations.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).

 

Evaluated to the following...

 

This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.

 

These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.

 

All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.

 

All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C". 

Listing Report Return to Search
Attributes
CriteriaUL 10(c) (1998)
CriteriaNFPA 252 (1999)
CriteriaUL 10(c) (2009)
CriteriaNFPA 252 (2012)
CriteriaUL 10(c) (2016)
CSI Code08 10 00 Doors and Frames
CSI Code08 14 00 Wood Doors
Fire Resistance20 Min w/out Hose Positive Pressure
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID22193
SwingSingle Swing
SwingStandard Pairs