Deansteel 20-90 Min Steel Fire Doorframe for Stalprofil Glazed Wall Systems Company: Deansteel Manufacturing Company, Inc.

Pressed Steel (14, 16, 18 gauge) Door Frames, (20, 45, 60, 90 minutes), Single Rabbet, Welded-Up for installation in Stalprofil glazed wall systems (20, 45, 60, 90, 120 minutes). Category C Proprietary Frame

 

Minimum Throat Openings

20 - 60 minute frame for Stalprofil 60 minute fire-rated wall  2-1/16"

90 minute frame for Stalprofil 120 minute fire-rated wall  2-15/16"

Maximum Sizes

Single Swing     4' 0" wide x 10' 0" high

Standard Pairs  8' 0" wide x 10' 0" high

Testing Standards

UBC-7-2-97/UL-10C (Positive Pressure)

Evaluated to the following:

This category includes frames not based on ANSI-A155.1/UL-63 construction Type (such as aluminum, wood, light gauge steel, composite, etc.). These listings will reference specific door types for which each frame is qualified. All frames listed in this section may be used in positive pressure assemblies per the terms and limitations of the individual listing.

All frames in this category are identified by a label or marking bearing the wording, "Listed Fire Door Frame", the Warnock Hersey Certification Mark, "UBC-7-2-97/UL-10C. Frames rated at less than 3 hours will have a time interval noted on the label/marking.

Listing Report Return to Search
Attributes
CriteriaUL 10(c) (1998)
CriteriaUBC 7-2 (1997)
CriteriaUL 10(c) (2009)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min PP Category C Proprietary Frame
Fire Resistance45 Min PP Category C Proprietary Frame
Fire Resistance60 Min PP Category C Proprietary Frame
Fire Resistance90 Min PP Category C Proprietary Frame
Listing SectionCATEGORY C - PROPRIETARY FRAMES
Spec ID22267
SwingSingle Swing
SwingStandard Pairs