Keim Cat. B 20 Min. Wood Stile & Rail Doors w/out hose Company: Keim Lumber Company

Panel Type (Proprietary Construction), Swing Stile & Rail Design Fire Door for installation single or in pairs in 20 minute locations.


Limitations:
Unit (Preassembled), Cylindrical Latches/Deadbolts/Surface Mounted Rim Type Fire Exit Hardware/Mortised or Surface Mounted Automatic or Manual Top & Bottom (Flush) Bolts/Surface Mounted Vertical Rod Fire Exit Hardware/Vision panel – not allowed/Viewers/Plant-Ons-Applied Mouldings

 

Maximum Size of Openings:

Singles - 3'0" wide x 7'0" high
Pairs – Not Allowed

 

This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.

These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.

All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.

All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL-10C". See Positive Pressure Section Header for more information.
 

Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:

 

ASTM-E152, Methods of Fire Tests of Door Assemblies
NFPA-252, Standard Methods for Fire Tests of Door Assemblies
UBC-7-2-94, Uniform Building Code
UBC-7-2-97, Uniform Building Code
UL-10(b), Fire Tests of Door Assemblies
UL-10(c), Fire Tests of Door Assemblies
and are installed in accordance with the following:
NFPA-80, Fire Doors and Windows


Manufacturer's Instructions:

All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.

 

Listing Report Return to Search
Attributes
CriteriaUL 10(c) (1998)
CriteriaUBC 7-2 (1997)
CriteriaUBC 7-2 (1994)
CriteriaUL 10(b) (1997)
CriteriaNFPA 252 (2003)
CriteriaASTM E152-81AE02
CriteriaUL 10(b) 2008 (R2009)
CriteriaUL 10(c) (2009)
CSI Code08 10 00 Doors and Frames
Fire Resistance20 Min w/out Hose Positive Pressure
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID22447
SwingSingle Swing