CATEGORY G - EDGE-SEALING SYSTEMS
HSS1000 Intumescent Fire Seal for installation in Listed Wood (Particleboard/Staved Lumber/PSL) Fire Doors, with Full Lite Vision Panels, installed in Steel Fire Dooframes (22 gauge or welded) in Drywall or Masonry walls, rated 20 minutes without hose stream.
Configuration
|
Maximum Size*
|
Single Swing
|
4'0" wide x 8'0" high (Method 1)
|
HSS2000 Intumescent Fire Seal for installation in Listed Wood (Particleboard/Staved Lumber/PSL) Fire Doors, with Full Lite Vision Panels, installed in Steel Fire Dooframes (22 gauge or welded) in Drywall or Masonry walls, rated 20 minutes without hose stream.
Configuration
|
Maximum Size*
|
Single Swing
|
4'0" wide x 9'0" high (Method II)
|
*Refer to manufacturer's installation instructions for additional details.
Testing Standards: UBC-7-2-97 Parts I and II.
Evaluated to the following...
These Category G - Edge-Seal Systems are for use in Category B doors. These systems are surface-applied to the perimeter of the door or frame. They may be kerf-applied, adhesive-backed, or mechanically fastened.
Edge-sealing systems are identified by a label or marking bearing the appropriate Warnock Hersey Certification Mark.
GLAZING COMPOUND
FG3000S45 Fire Glaze glazing compound for installation in Listed Wood (Particleboard/Staved Lumber/PSL) Fire Doors, with Full Lite Vision Panels, installed in Steel Fire Dooframes (22 gauge or welded) in Drywall or Masonry walls, rated 20 minutes without hose stream.
Configuration
|
Maximum Size*
|
Single Swing
|
4'0" wide x 9'0" high
|
*Refer to manufacturer's installation instructions for additional details.
Testing Standards: UBC-7-2-97, UL 10C, and NFPA 252.