CATEGORY G - EDGE-SEALING SYSTEMS
HSS1000 Intumescent Fire Seal for installation with Listed Wood Fire Doors installed in Wood Fire Door Frames with Sidelights rated 20 minutes.
Configuration |
Max. Size* |
Single Swing |
3'6" wide x 8'0" high |
HSS1000/HSS2000 Intumescent Fire Seal for installation with Listed Wood Fire doors installed in Wood, Steel, Aluminum Fire Door Frames rated 20 minutes.
Configuration |
Max. Size* |
Single Swing |
4'0" wide x 9'0" high |
Standard Pair |
8'0" wide x 9'0" high |
HSS2000, Intumescent Material for installation on Listed Steel and Wood Frames with listed Wood/Mineral Core doors. Surface applied with self-stick tape to either door edges or to frame head and jambs (see manufacturer's instructions).
Edge Sealing |
HSS2000 |
Max. Rating |
20 minute |
Max. Size |
Single: 4'0" wide x 9'0" high
Pairs: 8'0" wide x 9'0" high |
Door Type |
Craftcore (Masonite) Flush, Profiled; Particleboard Core; Stave Core |
Frame Type |
Wood with a Minimum SG = 0.47*; Min. 22 gauge Steel (Standard, adjustable) |
Comments |
Craftcore (without hose stream): 3'0" wide x 8'0" high (Single Swing) & 7'0" wide x 7'0" high (Pair);
Wood Frame with SG < 0.47: 3'0" wide x 7'0" high (Single);
3, 4 point latching on pairs with concealed, surface mounted hardware. |
HSS2000 Intumescent Fire Seal for installation with Listed Steel Skinned Foam Filled Fire Doors installed in Steel Fire Door Frames rated 20 minutes (without hose stream).
Configuration |
Max. Size* |
Single Swing |
3'0" wide x 6'8" high |
HSS2000 Intumescent Fire Seal for installation with Listed Craft Core (refer to Masonite Listings) Fire doors installed in Wood, Steel, Aluminum Fire Door Frames rated 20 minutes.
Configuration |
Max. Size* |
Single Swing |
3'6" wide x 7'0" high |
Single Swing |
3'0" wide x 8'0" high |
Standard Pair |
7'0" wide x 7'0" high |
*Refer to manufacturer's installation instructions for additional details.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).
Evaluated to the following...
This category includes field-applied systems only. Category G - Edge-Seal Systems are for use in Category B doors, or meeting edges (only) of Category A doors. These systems are surface-applied to either the perimeter of the door or frame, or meeting edge of the door. They may be kerf-applied, adhesive-backed, or mechanically fastened.
Edge-sealing systems are identified by a label or marking bearing the Warnock Hersey Certification Mark.
CATEGORY H - SMOKE & DRAFT CONTROL GASKETING
Extruded Thermal Plastic Rubber Smoke and Draft Control Gasketing, Model Nos. PK4, PK52. (See manufacturer's instructions).
S3 Smoke & Draft Control Gaskets for installation with Listed Fire Door Assemblies.
Door Type |
Frame Type |
Configuration |
Max. Size |
Application |
20 minute Wood Door |
Wood, Steel, Aluminum |
Single Swing
Standard Pair |
4'0" wide x 9'0" high
8'0" wide x 9'0" high |
Perimeter |
20 minute without Hose Foam Filled Steel Door |
Steel |
Single Swing |
3'0" wide x 6'8" high |
Perimeter |
20 minute without Hose Craft Core (Masonite) Door |
Wood, Steel |
Single Swing
Standard Pair |
3'6" wide x 7'0" high
3'0" wide x 8'0" high
7'0" wide x 7'0" high |
Perimeter |
S4, PK4 Smoke & Draft Control Gaskets for installation with Listed Fire Door Assemblies.
Door Type |
Frame Type |
Configuration |
Max. Size |
Application |
20 minute Wood Door |
Wood, Steel, Aluminum |
Single Swing
Standard Pair |
4'0" wide x 9'0" high
8'0" wide x 9'0" high |
Perimeter |
20 minute without Hose Foam Filled Steel Door |
Steel |
Single Swing |
3'0" wide x 6'8" high |
Perimeter |
20 minute without Hose Craft Core (Masonite) Door |
Wood, Steel |
Single Swing
Standard Pair |
3'6" wide x 7'0" high
3'0" wide x 8'0" high
7'0" wide x 7'0" high |
Perimeter |
S44/S88 Fire & Smoke Seal for installation with Listed Wood Core Fire Doors installed in Wood Door Frames rated 20 minutes.
Configuration |
Max. Size* |
Single Swing |
4'0" wide x 9'0" high |
Standard Pair |
8'0" wide x 9'0" high |
S44/S88, Vinyl Bulb Gasketing for installation on Listed Wood frames with Listed Wood Core Doors. Surface applied with self-stick tape to head and jambs (see manufacturer's instructions).
Edge Sealing |
S44/S88 |
Max. Rating |
20 minute |
Max. Size |
Single: 4'0" wide x 9'0" high
Pairs: 8'0" wide x 9'0" high |
Door Type |
Particleboard Core; Stave Core |
Frame Type |
Wood with a Minimum SG = 0.47 |
Comments |
4-point latching on pairs with surface mounted hardware |
S44/S88 Smoke & Draft Control Gaskets for installation with Listed Fire Door Assemblies.
Door Type |
Frame Type |
Configuration |
Max. Size |
Application |
20 minute Wood Door |
Wood, Steel, Aluminum |
Single Swing
Standard Pair |
4'0" wide x 9'0" high
8'0" wide x 9'0" high |
Perimeter |
20 minute without Hose Foam Filled Steel Door |
Steel |
Single Swing |
3'0" wide x 6'8" high |
Perimeter |
20 minute without Hose Craft Core (Masonite) Door |
Wood, Steel |
Single Swing
Standard Pair |
3'6" wide x 7'0" high
3'0" wide x 8'0" high
7'0" wide x 7'0" high |
Perimeter |
S88 Fire & Smoke Seal for installation with Listed Wood Core Fire Doors installed in Steel Door Frames rated 20 minutes.
Configuration |
Max. Size* |
Single Swing |
3'0" wide x 8'0" high |
*Refer to manufacturer's installation instructions for additional information on Smoke & Draft Control.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).
Evaluated to the following...
This category includes gasket systems that are surface-applied (such as kerf-applied, adhesive-backed, or mechanically-attached) to frames or doors. It includes gasketing for the meeting edges for use in pair and double egress assemblies.
Note: This category covers gasket systems that have been evaluated for use in positive pressure rated assemblies, but do not provide an edge-sealing system to the opening (see Category G). These gasket systems have been evaluated in accordance with UBC 7-2, Parts I and II.
All smoke & draft control gasketing systems are identified by a label or marking bearing the Warnock Hersey Certification Mark.