SAFTI FIRST Superlite Ceramic IGU insulated glass unit Up to 180 minutes NEW Company: SAFTI FIRST

Superlite Ceramic IGU insulated glass unit for use in Fire Doors and Fire Windows, Door Side Lights and Transoms in up to 180 minute locations in labeled steel frames. 

Superlite C, C/P, Superceram & Pyran™ Platinum  (5mm thick Glazing)

 

Rating:

Application:

Max Area:

Max W:

Max H:

Stop H:

20-90 Minute

Sidelites, Fire Windows, & Transom in Steel frames

3323

77-3/4

77-3/4

5/8

 * Assemblies must be rated per application.

 

 

 

Superlite C/S, C/SP, Superceram F & Pyran™ Platinum F (5mm thick Glazing)

 

 

Rating:

Application:

Max Area:

Max W:

Max H:

Stop H:

20-90 Minute

Sidelites, Fire Windows, & Transom in Steel frames

3323

77-3/4

77-3/4

5/8

20-90 Minute

Wood/Wood Composite or Steel Doors (non-temp rise)

2799

36

77-3/4

5/8

Up to180 Minute

Wood/Wood Composite or Steel Doors (non-temp & temp rise)

100

10

33

5/8

 * Assemblies must be rated per application.

 

 

(S) = Safety Film

(F) = Safety Film

 

 

 

Listed products are intended to be installed, unless otherwise noted, in accordance with the following:

NFPA-80, Fire Doors & Windows 

 

Manufacturer's Instructions.

 

Listed maximum sizes of glazing are based on sizes tested and may exceed those allowed by local codes. Dependent on the end use installation, local codes may require that additional criteria be met to address considerations such as radiant heat hazards and impact safety. Under such circumstances, the prior approval of the Authority Having Jurisdiction must be obtained unless conformance to relevant additional requirements is indicated within the individual listing.

 

Clearance between the edges if the glazing and the inside edge of the frame shall not exceed 1/8" unless otherwise noted in the individual listing or the manufacturer’s installation instructions.

 

All glazing is identified by an etched mark or label bearing the WHI Certification Mark or ETL Mark.

 

Listed products are intended to be installed, unless otherwise noted, in accordance with the following:

NFPA-80, Fire Doors & Windows 

 

Listing Report Return to Search
Attributes
CriteriaNFPA 257 (2000)
CriteriaUL 9 (2000)
CriteriaCAN4 S106 (1985)
CriteriaCAN / ULC S104 (1980) (R1985)
CriteriaUL 10(c) (R2001)
CriteriaUL 10(b) (2008)
CriteriaNFPA 252 (2008)
CriteriaUL 9 (2005)
CriteriaNFPA 257 (2007)
CriteriaUL 10(b) 2008 (R2009)
CriteriaUL 10(c) (2009)
CSI Code08 80 00 Glazing
Fire Resistance45 Min Neutral Pressure
Fire Resistance90 Min Neutral Pressure
Fire Resistance3 Hour Neutral Pressure
Fire Resistance60 Min Neutral Pressure
Fire Resistance45 Min Positive Pressure
Fire Resistance90 Min Positive Pressure
Fire Resistance60 Min Positive Pressure
Fire Resistance3 Hour Positive Pressure
Fire Resistance20 Min Neutral Pressure
Fire Resistance20 Min Positive Pressure
Listing SectionGLAZING/GLASS
Spec ID23160
Design Documents
No Results
Public Documents
No Results