Stainless Steel-Faced (14, 16, 18 gauge) Stainless Steel-stiffened Swinging Flush Door for installation in up to 90 minute locations. For use in listed (3-sided) 16 gauge (14, 12 gauge) welded steel or stainless steel frames meeting ANSI-A155.1/UL-63 or per frame manufacturer's listing(s).
Limitations:
Mortise or Cylindrical Latches with maximum 5" backset/Mortise Exit Devices/Surface Mounted Vertical Rod Fire Exit Devices/Rim Type Fire Exit Devices/Concealed Vertical Rod Exit Devices/Deadbolts/Extension Bolts with a maximum extension of 12"/Surface bolts/Automatic Flush Bolts/Surface Mounted Closers/concealed Closer Arms/Surface Mounted Protection Plates/Viewer/Open-Back Strikes/Louver/Electric Raceway/Vision Light Kit/Surface Mounted or Mortised Door Bottoms/Astragal Required on All Pairs/Temperature Rise - Greater than 650°F at 30 minutes.
| Configuration |
Max. Size |
| Single Swing |
3'0" wide x 8'0" high |
| Standard Pair |
6'0" wide x 8'0" high |
| Double Egress |
N/A |
| Labeled Material |
Specifications |
1-1/2 Hour |
1 Hour |
3/4 Hour |
| 1/4" Wired Glass |
Area |
100"2 |
100"2 |
1296"2 |
| Width |
12" |
12" |
54" |
| Height |
33" |
33" |
54" |