LIF 20 - 90 Minute Positive Pressure Fire Rated Door Frames Company: LIF Industries

Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Single Unit Pressed Steel Door Frames
 
Product Description:
These frames are intended for the installation of hollow metal fire doors.
 
Sizes:
      MAX. FRAME OPENING:
  • Single Swing: 4'0" x 8'0"
  • Standard Pair: 8'0" x 8'0"
  • Double Egress: 8'0" x 8'0"

Product Covered:
LIF 45 - 90 Minute Fire Rated Single Unit Pressed Steel Door Frames with Transom Panel or Transom Lite, and/or Side Panels or Side Lites
 
Product Description:
These frames are intended for installation with Listed and labeled fire doors.
 
Frames incorporating solid panels are for use with doors rated 90 Minutes.
 
Frames incorporating transom lites and/or side lites glazed with 1/4 in. thick wired glass are for use with doors rated 45 Minutes.
 
EXCEPTION: Fire door frame assemblies rated for 60 Minutes and equipped with transom lites and/or side lites for walls at least 4-7/8 in. thick.  These frames are intended for installation with fire doors rated 60 Minutes, and must use Firelite glazing material. 
 
Sizes:
 
      MAX. FRAME OPENING:
 
  • 12' 0" wide x 11' 4" high
  • Total opening shall not exceed 136 sq. ft.
  • Doors:
    • Max. 8' 0" x 8' 0"
  • Individual Transom Panels:
    • Max. Width: 3' 0"
    • Max. Height: 4' 0"
  • Individual Side Panels:
    • Max. Width:  2' 9"
    • Max. Height: 3' 4"
  • Individual Transom/Side Lites:
    • Max. Width: 3' 0"
    • Max. Height: 4' 0"
    • Max. Opening: 1296 sq. in. 

 
Product Covered:
LIF 90 Minute Fire Rated Single Pressed Steel Door Frames with Solid Transom Panels
 
Product Description:
Frames incorporating solid transom panels are for use with doors rated up to and including 90 minutes.
 
Sizes:
      MAX. FRAME OPENING:
  • 7' 0" wide x 11' 2" high
  • Transom Panel:
    • Max. Width: 7' 0"
    • Max. Height: 4' 0"

Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Single Unit Pressed Steel Door Frames for non-masonry walls at least 2 in. thick.
 
Product Description:
These frames are intended for the installation of Listed and labeled single swing fire doors.
 
Sizes:
      MAX. FRAME OPENING:
  • "PF" Type Frame
    • 3' 10" wide x 8' 0" high
  • "NS" Type Frame
    • 3' 10" wide x 7' 0" high

Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Fire Door Frame with Lites
 
Product Description:
These frames are intended for the installation of Listed and labeled 20 Minute Fire Rated doors.
 
These frames, incorporating lites, are intended to be glazed with 1/4 in. thick wired glass.
 
Sizes:
      MAX. FRAME OPENING:
  • 13' 2" wide x 11' 7" high
  • Doors:
    • Single Swing: 4' 0" x 10' 0"
    • Standard Pair: 8' 0" x 10' 0"
  • Individual Transom/Side Lites:
    • Max. Width: 8' 5.5"
    • Max. Height: 8' 5.5"
    • Max. Area: 3831 sq. in.

 
Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Single Unit Pressed Steel Door Frame
 
Sizes: 
      FRAME OPENING:
    • Maximum Width: 8'0"
    • Maximum Height: 8'0"
    • Jamb Depth: Minimum 4", Maximum 12"
      DOOR SIZE:
    • Maximum Width: 8'0" Nominal
    • Maximum Height: 8'0" Nominal
 
Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Single Unit Pressed Steel Door Frame for Double Egress Doors 
 
Product Description:
These frames are intended for the installation of hollow metal fire doors swinging in pairs (opposite directions).
 
Sizes:
      MAX. FRAME OPENING
  • Single Swing: 4' 0" wide x 8' 0" high
  • Standard Pair: 8' 0" wide x 8' 0" high
  • Double Egress: 8' 0" wide x 8' 0" high

Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Two-Section Type with Pressed Steel Rough Bucks Door Frames
 
Sizes:
      OVERALL FRAME SIZE:
    • Maximum Width:
    • Maximum Height:
    • Jamb Depth: Minimum 4", Maximum 12"
      DOOR SIZE:
            Single Swing:
    • Maximum Width: 4'0"
    • Maximum Height: 10' 0"
            Standard Pairs:
    • Maximum Width: 8'0"
    • Maximum Height: 10' 0"
 
Product Covered:
LIF 90 Minute Fire Rated Single Pressed Steel Door Frames with Hollow-Metal Transom Panels
 
Product Description:
Frames incorporating hollow-metal panels are for use with doors rated up to 90 Minutes. 
 
Sizes:
      MAX. FRAME OPENING
  • 7' 0" wide x 11' 2" high
  • Transom Panel:
    • Max. Width: 7' 0"
    • Max. Height: 4' 0"

Product Covered:
LIF 45 - 90 Minute Fire Rated Single Unit Pressed Steel Door Frames with Transom Panel or Transom Lite, and/or Side Panels or Side Lites
 
Product Description:
These frames are intended for installation with Listed and labeled fire doors swinging in pairs or single swing.
 
Frames incorporating steel clad panels are for use with fire doors rated 90 Minutes.
 
Frames incorporating transom lites and/or side lites are intended to be provided with 1/4 in. thick Listed and labeled wired glass are for use with fire doors rated 45 Minutes.
 
Sizes:
      MAX. FRAME OPENING
  • 12' 0" wide x 11' 4" high
  • Max. Area: 120 sq. ft.
  • Doors:
    • Single Swing: 4' 0" x 8' 0"
    • Standard Pair: 8' 0" x 8' 0"
  • Transom Panels:
    • Max. Width: 3' 0"
    • Max. Height: 4' 0"
  • Side Panels:
    • Max. Width: 2' 9"
    • Max. Height: 4' 6"
  • Transom Lites:
    • Max. Width: 3' 0"
    • Max. Height: 4' 0"
    • Max. Area: 1296 sq. in.
  • Side Lites:
    • Max. Width: 2' 9"
    • Max. Height: 4' 6"
    • Max. Area: 1296 sq. in.

Product Covered:
LIF 90 Minute Fire Rated Pressed Steel Door Frames incorporating Hollow-Metal Transom Panels
 
Product Description:
Frames incorporating hollow-metal panels are for use with doors rated up to 90 Minutes. 
 
Sizes:
      MAX. FRAME OPENING
  • 4' 0" wide x 9' 10" high
  • Transom Panel:
    • Max. Width: 4' 0"
    • Max. Height: 3' 2"

 
Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Pressed-Steel Type Door Frame for Double Egress Doors
 
Product Description:
Frames for use with 20 Minute Listed and labeled fire rated double egress doors or single swing doors.
 
Sizes:
      MAX. FRAME OPENING
  • Single Swing: 4' 0" x 8' 0"
  • Standard Pair: 8' 0" x 8' 0"
  • Double Egress: 8' 0" x 8' 0"

 
Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Single Unit Pressed Steel Door Frame for use with Double Egress Doors
 
Product Description:
These frames are intended for the installation of hollow metal Listed and labeled double egress fire doors.
 
Sizes:
      MAX. FRAME OPENING
  • Single Swing: 4' 0" x 8' 0"
  • Standard Pair: 8' 0" x 8' 0"
  • Double Egress: 8' 0" x 8' 0"

 
Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Single Unit Pressed Steel Door Frame
 
Product Description:
These frames are intended for the installation of hollow metal Listed and labeled fire doors for walls at least 4 in. thick.
 
Sizes:
      MAX FRAME OPENING
  • Maximum Width: 12' 0"
  • Maximum Height: 8' 0"

 
Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Single Unit Pressed Steel KD Door Frame
 
Product Description:
These frames are intended for the installation of single swing hollow metal Listed and labeled fire doors for non-masonry walls at least 2 in. thick.
 
Sizes:
      MAX FRAME OPENING
  • Maximum Width: 8' 0"
  • Maximum Height: 8' 0"

  
Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Steel Door Frame
 
Product Description:
These frames are intended for the installation of 20 Minute Fire Rated Listed and Labeled doors fire tested without hose stream, single swinging or swinging in pairs.
 
These frames, incorporating lites, are intended to be glazed with Listed and Labeled 1/4 in. thick classified wired glass.
 
Sizes:
      OVERALL FRAME SIZE
  • Maximum Width: 9' 6"
  • Maximum Height: 9' 0"
      TRANSOM/SIDE LITES
  • Maximum Width: 5' 10"
  • Maximum Height: 5' 10"
  • Maximum Area: 3220 sq. in.

  
Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Steel Door Frames
 
Product Description:
These frames are intended for the installation of 20 Minute Fire Rated Listed and Labeled doors fire tested without hose stream, single swinging or swinging in pairs.
 
These frames, incorporating lites, are intended to be glazed with Listed and Labeled 1/4 in. thick classified wired glass.
 
Sizes:
      MAX OVERALL FRAME SIZE
  • Maximum Width: 13' 2"
  • Maximum Height: 11' 7"
      MAX DOOR SIZE
  • Maximum Width: 8' 0"
  • Maximum Height: 10' 0"
      TRANSOM LITES
  • Maximum Width: 101-1/2"
  • Maximum Height: 101-1/2"
  • Maximum Area: 3831 sq. in.

 
Product Covered:
LIF 90 Minute Fire Rated Special Purpose Frame Assembly
 
Product Description:
These frames are intended for the installation of Fire Rated Listed and Labeled doors, single swinging or swinging in pairs.
 
Sizes:
      Single Swing:
  • Maximum Width: 4' 0"
  • Maximum Height: 8' 0"
      Standard Pairs:
  • Maximum Width: 8' 0"
  • Maximum Height: 8' 0"

  
Product Covered:
LIF 20 Minute Fire Rated w/o Hose Stream Pressed Steel Double and Single Rabbetted Door Frames
 
Product Description:
These frames are intended for the installation of Fire Rated Listed and Labeled doors, single swinging or swinging in pairs for walls at least 4 in. thick.
 
Sizes:
      Single Swing:
  • Maximum Width: 4' 0"
  • Maximum Height: 8' 0"
      Standard Pairs:
  • Maximum Width: 8' 0"
  • Maximum Height: 8' 0"

  
Product Covered:
LIF 90 Minute Fire Rated Flat Trim Hollow Metal Steel Door Frames.
 
Product Description:
These frames are intended for the installation of Fire Rated Listed and Labeled doors, single swinging or swinging in pairs for fire rated drywall wall configurations.
 
Sizes:
      Single Swing:
  • Maximum Width: 4' 0"
  • Maximum Height: 8' 0"
  • Maximum Jamb Depth: 6-1/8"
      Standard Pairs:
  • Maximum Width: 8' 0"
  • Maximum Height: 8' 0" 
Maximum Jamb Depth: 6-1/8"

OVERALL LISTING NOTE:

MOLDING:
  • Wood molding detailed in and installed according to LIF Drawing 5244T may be applied to LIF 20 - 60 Minute Fire Rated Single Swing Steel Door Frames that have a maximum door leaf size of 3'6" x 8'0".  Wood moulding shall be applied with the use of Silicone Adhesive SCS1000.  Please note that this allowance is in regard to door frames only, and does not include installation on transom and/or side lite/panel frame members.  The door used for this frame application must be a listed wood door with intumescent seals as required by the door listing.  The use of steel doors is not permitted with this application.
    • The molding can be veneered with Lacewood or other hardwood (minimum s.g. 0.47) with a thickness of 0.030" to 0.090"
    • HPL meeting NEMA LD-3 can also be used to cover the moulding. 
    • Moulding has MDF base (1/2")  with a density of 47 pcf
 
Listing Report Return to Search
Attributes
CriteriaNFPA 252 (2012)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CriteriaUL 10(b) (2008) (R2015)
CSI Code08 10 00 Doors and Frames
Fire Resistance45 Min Positive Pressure
Fire Resistance20 Min w/out Hose Positive Pressure
Fire Resistance60 Min Positive Pressure
Fire Resistance90 Minute Fire Rated
Listing SectionDOOR FRAMES
Spec ID23602