Specified Technologies SpecSeal AS Elastomeric Firestop Spray - Cat No AS205 and AS205R Company: Specified Technologies, Inc.

SpecSeal AS Elastomeric Firestop Spray (Cat No. AS205 and AS205R)

Client Description
SpecSeal® AS Elastomeric Firestop Spray AS205 and AS205R (AS200 Series) are non-halogenated elastomeric coatings designed to provide passive fire protection in construction joints.  Both products are a single component material which is either spray or brush applied over an insulative material that acts as a support and then becomes an integral part of the system.

RATINGS
Standard Rating Design Number
ASTM E2307 F-Rating 120 Minutes STI/BPF 120-01
ASTM E2307 F-Rating 120 Minutes STI/BPF 120-02
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-07
ASTM E2307 F-Rating 120 Minutes,
T-Rating 60 Minutes
STI/BPF 120-08
ASTM E2307 F-Rating 120 Minutes,
T-Rating 60 Minutes
STI/BPF 120-09
ASTM E2307 F-Rating 120 Minutes,
T-Rating 90 Minutes
STI/BPF 120-10
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-11
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-12
ASTM E2307 F-Rating 120 Minutes,
T-Rating 40 Minutes
STI/BPF 120-13
ASTM E2307 F-Rating 120 Minutes,
T-Rating 40 Minutes
STI/BPF 120-14
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-15
ASTM E2307 F-Rating 120 Minutes,
T-Rating 60 Minutes
STI/BPF 120-16
ASTM E2307 F-Rating 120 Minutes,
T-Rating 40 Minutes
STI/BPF 120-17
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-18
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-19
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-24
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-25
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-26
ASTM E2307 F-Rating 120 Minutes,
T-Rating 45 Minutes
STI/BPF 120-27
EN 1364-4 Integrity Rating 150 Minutes,
Insulation Rating 150 Minutes
STI/BPF 150-01
ASTM E2307
CAN/ULC S115
F-Rating 180 Minutes,
T-Rating 105 Minutes
STI/BPF 180-01
ASTM E2307
CAN/ULC S115
F-Rating 180 Minutes,
T-Rating 120 Minutes
STI/BPF 180-02
ASTM E1966 120 Minutes STI/JF 120-01
ASTM E2307
CAN/ULC S115
F-Rating 90 Minutes,
T-Rating 60 Minutes
STI/BPF 90-02
Listing Report Return to Search
Attributes
CriteriaUL 2079 Air Leakage (2004)
CriteriaASTM E1399 Cycling
CriteriaASTM E2307 (2004) e1
CriteriaASTM E1966 (2007)
CriteriaASTM E1354 (2014 E1)
CriteriaASTM E2307 (2015)
CriteriaEN 1364-4 (2014)
CriteriaCAN / ULC S115 (2018) Ed. 5
CriteriaASTM E2307 (2019)
CriteriaASTM E2307 (2020)
CSI Code07 84 53 Building Perimeter Firestopping
Listing SectionFIRESTOP SYSTEMS
Spec ID23723
Test TypeFire Resistance