Koch & Co. 20 Min Wood Stile & Rail Door
Wood Panel Doors, Swinging Flush for installation in up to 20 minutes (without hose stream) locations. For use in listed (3-sided) 16 gauge welded steel frames meeting ANSI-A155.1/UL-63 or as per frame manufacturer's listing(s).
Limitations*
Cylindrical and Mortise Latches with maximum 2-3/4" backset/Surface Mounted Vertical Rod Fire Exit Devices/Rim Type Fire Exit Devices/Deadbolts/Surface Mounted Closers/Surface Mounted Protection Plates/Plant-Ons/Viewer/Surface Mounted door bottoms.
Configuration |
Maximum Size |
Single Swing |
3'0" wide x 8'0" high |
Standard Pairs |
NA |
Double Egress Pairs |
NA |
*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions, and limitations.
Testing Standards
UBC-7-2-97/UL-10C (Positive Pressure).
Evaluated to the following:
This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.