Intertek Directory of Building Products

ABS Infinity/Millenium 45-60 Min Fire Door with Inlay Moulding PP Company: ABS

Mineral Core Type Swinging Flush Design Fire Door with Inlay Moulding for installation singly or in pairs in up to 60 minutes. For use in any Category C Standard Frame.
 
Limitations:
Cylindrical with 2-3/4" Backset / Surface Bolts / Surface Mounted Vertical Rod Fire Exit Hardware / Surface Mounted Closer / Automatic Door Bottoms / Viewer / Temperature Rise 250°F at 30 minutes. 
 
 
Configuration Maximum Size*
Single 4' 0" wide x 8' 0" high
Pairs 8' 0" wide x 8' 0" high
Double Egress N/A
 
 
*See manufacturer's installation instructions for additional information, restrictions and limitations.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).
 
Evaluated to the following...
 
This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.
 
These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
 
All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
 
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C". 
Listing Report Return to Search
Attributes
CriteriaUBC 7-2 (1997)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CSI Code08 10 00 Doors and Frames
Fire Resistance45 Min PP Category B Door
Fire Resistance60 Min PP Category B Door
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID24853
SwingSingle Swing
SwingStandard Pairs
Temperature Rise@ 30 Min = 250° F MAX Where Lites Do Not Exceed 100 IN2