Wood Core Type (Particle Board) (Fiberglass Reinforced Plastic-Faced), Swinging Flush Design Fire Door for installation singly or in pairs in 45 minute locations.
Limitations: Unit, Mortise/Cylindrical Latches with a maximum of 2-3/4" Backset/Surface Mounted/Mortised Manual Top and Bottom (Flush) Bolts/Lights - 667 sq.in./Metal Edges with astragal required.
Maximum Size of Openings: |
Singles - 50-1/4" wide x 96" high Pairs - 100-1/2" wide x 96" high |
Maximum Clear View Opening |
Louvers - 10-5/8" wide x 16-5/8" high or 176.64 sq.in. |
Evaluated to the following:
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies
CSFM-43.7, Methods of Fire Tests of Door Assemblies
CAN4-S104(ULC-S104), Standard Method for Fire Tests of Door Assemblies
NFPA-252, Standard Methods for Fire Tests of Door Assemblies
UBC-7-2-94, Uniform Building Code
UL-10(b), Fire Tests of Door Assemblies
and are installed in accordance with the following:
NFPA-80, Fire Doors and Windows
Manufacturer's Instructions.
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".)