Intertek Directory of Building Products

Eggers 90 Min Pairs with Lites Fire Doors Company: Eggers Division, LLC

Composite Core Type, Swinging Fire Door for installation in standard pairs 1-1/2 hour locations.

Maximum Size of Openings

Standard Pairs    8'0" wide x 9'0" high (each leaf 4'0" wide x 9'0" high)

Limitations

Mortise or Cylindrical Latches with up to a 5" Backset/Mortised or Surface Mounted Rim Type Fire Exit Hardware/ Lights - 1296 sq.in./Surface Mounted Vertical Rod Fire Exit Hardware.

Evaluated to the following:

This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.

Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.

All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.

 

Listing Report Return to Search
Attributes
CriteriaCAN4 S104 (1985)
CriteriaNFPA 252 (2008)
CriteriaUL 10(c) (1998) (R2001)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CSI Code08 14 00 Wood Doors
Fire Resistance90 Min PP Category A Door
Fire Resistance90 Min Positive Pressure
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Listing SectionDOORS
Spec ID25053