Mineral Core Type, Swinging Flush Design Fire Door for installation singly or in pairs, in 45 Minute locations.
Limitations: Unit (Preassembled), Mortise or Cylindrical Latches with up to a 5" backset/ Deadbolts/Single Point Latches/Mortised or Surface Mounted Rim Type Fire Exit Hardware/ Surface Mounted Vertical Rod Fire Exit Hardware/Protective Plates up to 11"/Lights - up to 1,200 in
2 (Single Swing), 100 in
2 (Pairs)/Viewers/Mortised or Surface Mounted Automatic or Manual Top and Bottom (Flush) Bolts/Louver - up to 24" x 24"/Plant-Ons - Applied Mouldings/Electric Raceways/Surface Mounted Closers/DPS/Floor Closers.
| Configuration/Maximum Size of Openings |
| Singles |
4’-0” wide by 10’-0” high |
| Standard Pairs |
8’-0” wide by 8’-0” high |
| 8’-0” wide by 9’-0” high only when 5” Tectonite blocking construction is used. |
| Door/ Transom |
3’-0” wide by 9’-0” high |
| Transom |
3’-0” wide by 3’-4” high |
Mineral Core Type, Swinging Flush Design Fire Door for installation singly or in pairs, in 60 and 90 Minute locations.
Limitations: Unit (Preassembled), Mortise or Cylindrical Latches with up to a 5" backset/Deadbolts/Mortised or Surface Mounted Rim Type Fire Exit Hardware/Surface Mounted Vertical Rod Fire Exit Hardware/Protective Plates up to 48"/Surface Mounted Closers/Lights - up to 100 in
2 (Pairs 64 in
2)/Viewers/Mortised or Surface Mounted Automatic or Manual Top and Bottom (Flush) Bolts/Louvers - up to 24" x 24"/Plant-Ons - Applied Mouldings/Electric Raceways/Single Point Latches/DPS/Floor Closers.
| Configuration/Maximum Size of Openings |
| Singles |
4’-0” wide by 9’-0” high (veneer) |
| 4’-0” wide by 8’-0” high (plastic) |
| Standard Pairs |
8’-0” wide by 8’-0” high (veneer) |
| 8’-0” wide by 9’-0” high only when 5” Tectonite blocking construction is used. (60 minute) |
| Double Egress |
8’-0” wide by 8’-0” high |
| Door/Transom |
3’-0” wide by 9’-0” high (90 minute) |
| |
3’-0” wide by 10’-0” high (60 minute) |
| Transom |
3’-0” wide by 3’-4” high (60-90 minute) |
Evaluated to the following:
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
- ASTM-E152, Methods of Fire Tests of Door Assemblies
- CSFM-43.7, Methods of Fire Tests of Door Assemblies
- CAN4-S104(ULC-S104), Standard Method for Fire Tests of Door Assemblies
- NFPA-252, Standard Methods for Fire Tests of Door Assemblies
- UBC-7-2-94, Uniform Building Code
- UL-10(b), Fire Tests of Door Assemblies
and are installed in accordance with the following:
- NFPA-80, Fire Doors and Windows
Manufacturer's Instructions.
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".