Intertek Directory of Building Products

IDP 20 Minute through 3 Hour Steel Fire Door Frames Company: IDP, Inc.

Product Covered:

IDP 20 Minute to 3 Hour Steel Fire Door Frames.

 

Per: NFPA 252 (2008) Standard Methods of Fire Tests of Door Assemblies, UBC 7-2 (1994) Fire Tests of Door Assemblies, UBC 7-2 (1997) Fire Tests of Door Assemblies, UL 10B (2009) Fire Tests of Door Assemblies, UL 10C (2009) Positive Pressure Tests of Door Assemblies, and CAN4 S104 (1985) Standard Method for Fire Tests of Door Assemblies.

 

MAXIMUM SIZES:

STANDARD FRAMES

Single Swing

Maximum Width: 48"
Maximum Height: 120"
Minimum Wall Thickness: 2"

Standard Pairs

Maximum Width: 96"
Maximum Height: 120"
Minimum Wall Thickness: 2"

Double Egress Pairs

NOT PERMITTED

DOOR WITH FIXED BAR TRANSOM

Single Swing

Maximum Width: 48"
Maximum Height: 120"
Maximum Transom Width: 48"
Maximum Transom Height: 32"
Minimum Wall Thickness: 4"

Standard Pairs

Maximum Width: 96"
Maximum Height: 120"
Maximum Transom Width: 96"
Maximum Transom Height: 32"
Minimum Wall Thickness: 4"
 

Listing Report Return to Search
Attributes
CriteriaUBC 7-2 (1997)
CriteriaUBC 7-2 (1994)
CriteriaCAN4 S104 (1985)
CriteriaUL 63
CriteriaNFPA 252 (2008)
CriteriaUL 10(b) 2008 (R2009)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance45 Min PP Category C Standard Frame
Fire Resistance3 Hour PP Category C Standard Frame
Fire Resistance20 Min w/Hose Positive Pressure
Fire Resistance45 Min Positive Pressure
Fire Resistance90 Min Positive Pressure
Fire Resistance60 Min Positive Pressure
Listing SectionCATEGORY C - STANDARD FRAMES
Spec ID25130
SwingSingle Swing
SwingStandard Pairs
SwingTransom
Design Documents
No Results