Wood Core Type (Particle Board or Wood Block), Swinging Flush Design Fire Door for installation singly or in pairs, including double egress, in 20 minute locations.
Limitations: Mortise or Cylindrical Latches with up to a 5" Backset/Deadbolts/Surface Mounted Rim Type Fire Exit Hardware/Surface Mounted Vertical Rod Fire Exit Hardware/Mortise Type Fire Exit Hardware/Lights - 1,200 sq.in./Mortised or Surface Mounted Top and Bottom Bolts.
| Maximum Size of Openings: |
Singles - 4'0" wide x 9'0" high Pairs - 6'0" wide x 9'0" high or 8'0" wide x 8'0" high Double Egress - 6'0" wide x 9'0" high or 8'0" wide x 8'0" high |
Testing Standards: Tested per BOCA Basic/National, SBC, UBC requirements.
Note: For additional information please refer to the Weyerhaeuser - SLM listings.
Evaluated to the following:
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies
NFPA-252, Standard Methods for Fire Tests of Door Assemblies
UBC-7-2-94, Uniform Building Code
UL-10(b), Fire Tests of Door Assemblies
and are installed in accordance with the following:
NFPA-80, Fire Doors and Windows
Manufacturer's Instructions.
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".)