Summit Door 20 Min Wood Fire Door Frame w/Sidelight or Sidepanel and Borrowed Light Frame Company: Navy Island, Inc.

DOOR FRAMES

Wood Door Frame with or without Side Light or Side Panel for installation in 20 minute locations in steel/wood stud drywall or masonry openings.

Maximum Size of Openings: Frame only- Singles - 4'0" wide x 9'0" high
Pairs - 8'0" wide x 9'0" high
Frame with Side Light/Side Panel Assembly 10'6" wide x 9'0" high
Minimum Wall Thickness: 3-3/4"

Evaluated to the following:

Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UBC-7-2-94, Uniform Building Code;
UL-10(b), Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.

Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.

FIRE WINDOW FRAMES

Wood Fire Window Frame for installation in 20 minute locations in steel/wood stud drywall or masonry openings.

Maximum Individual Light Area: 1,296 sq.in.
Maximum Overall Dimensions: 7'0" wide x 8'8" high
Maximum Individual Light Dimensions: 54" wide x 54" high

Evaluated to the following:

Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E163, Methods of Fire Tests of Fire Window Assemblies.
CAN/ULC-S106, Standard Method for Fire Tests of Window & Glass Block Assemblies.
NFPA-257, Standard Method for Fire Tests of Fire Window Assemblies.
UBC-7-4-94, Uniform Building Code.
UL-9, Fire Tests of Window Assemblies.
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All assemblies are identified by a label or marking bearing the wording "Listed Fire Window Frame", a time interval, a serial number and the WHI Certification Mark.

Listing Report Return to Search
Attributes
CriteriaNFPA 252 (1995)
CriteriaASTM E152-81a
CriteriaUBC 7-2 (1994)
CriteriaUL 10(b) (1997)
CriteriaCAN / ULC S104 (1980) (R1985)
CriteriaUL 10(b) 2008 (R2009)
CriteriaCAN / ULC S104 (2010)
CSI Code08 10 00 Doors and Frames
Fire Resistance20 Min NP Fire Doorframe
Listing SectionDOOR FRAMES
Listing SectionFIRE WINDOW FRAMES
Spec ID25312
SwingSingle Swing