FIRE WINDOW FRAMES:
Roll Formed Steel Fire Window Frame (18, 20 gauge ) (Knock Down) (Steel Casing) for installation in 20 minute without hose stream and 45 minute locations in steel/wood stud drywall or masonry openings.
Fire Rating: |
20 Minute without Hose Stream |
45 Minute |
Maximum Overall Size |
10'1" wide x 10'1-3/4" high |
10'1" wide x 10'1-3/4" high |
Maximum Size of Lights (Clear View) |
22-3/4" wide
106-3/4" high
2400 sq.in. |
34-3/4" wide
54" high
1296 sq.in. |
Minimum Glazing Stop Height |
5/8" |
5/8" |
Minimum Wall Thickness |
3-1/2" |
3-1/2" |
Evaluated to the following:
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E163, Methods of Fire Tests of Fire Window Assemblies.
CAN/ULC-S106, Standard Method for Fire Tests of Window & Glass Block Assemblies.
NFPA-257, Standard Method for Fire Tests of Fire Window Assemblies.
UBC-7-4-94, Uniform Building Code.
UL-9, Fire Tests of Window Assemblies.
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All assemblies are identified by a label or marking bearing the wording "Listed Fire Window Frame", a time interval, a serial number and the WHI Certification Mark.
DOOR FRAMES:
Roll Formed Steel Door Frame (18, 20 gauge ) (Knock Down) (Steel Casing) for installation in 20 minute without hose stream and 45 minute locations in steel/wood stud drywall or masonry openings.
Fire Rating: |
20 Minute without Hose Stream |
45 Minute |
Maximum Overall Size |
10'1" wide x 10'1-3/4" high |
10'1" wide x 10'1-3/4" high |
Maximum Size of Lights (Clear View) |
22-3/4" wide
106-3/4" high
2400 sq.in. |
34-3/4" wide
54" high
1296 sq.in. |
Minimum Glazing Stop Height |
5/8" |
5/8" |
Minimum Wall Thickness |
3-1/2" |
3-1/2" |
Evaluated to the following:
Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UBC-7-2-94, Uniform Building Code;
UL-10(b), Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.