Intertek Directory of Building Products

Omega 45 Min Steel Door Frame w/Sidelights & Transom Lights and 45 Min Borrowed Light Company: Omega Door Frame Products, Inc.

FIRE WINDOW FRAMES:

Roll Formed Steel Fire Window Frame (18, 20 gauge ) (Knock Down) (Steel Casing) for installation in 20 minute without hose stream and 45 minute locations in steel/wood stud drywall or masonry openings.

Fire Rating: 20 Minute without Hose Stream 45 Minute
Maximum Overall Size 10'1" wide x 10'1-3/4" high 10'1" wide x 10'1-3/4" high
Maximum Size of Lights (Clear View) 22-3/4" wide
106-3/4" high
2400 sq.in.
34-3/4" wide
54" high
1296 sq.in.
Minimum Glazing Stop Height 5/8" 5/8"
Minimum Wall Thickness 3-1/2" 3-1/2"

 

Evaluated to the following:

Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E163, Methods of Fire Tests of Fire Window Assemblies.
CAN/ULC-S106, Standard Method for Fire Tests of Window & Glass Block Assemblies.
NFPA-257, Standard Method for Fire Tests of Fire Window Assemblies.
UBC-7-4-94, Uniform Building Code.
UL-9, Fire Tests of Window Assemblies.
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.

Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All assemblies are identified by a label or marking bearing the wording "Listed Fire Window Frame", a time interval, a serial number and the WHI Certification Mark.

DOOR FRAMES:

Roll Formed Steel Door Frame (18, 20 gauge ) (Knock Down) (Steel Casing) for installation in 20 minute without hose stream and 45 minute locations in steel/wood stud drywall or masonry openings.

Fire Rating: 20 Minute without Hose Stream 45 Minute
Maximum Overall Size 10'1" wide x 10'1-3/4" high 10'1" wide x 10'1-3/4" high
Maximum Size of Lights (Clear View) 22-3/4" wide
106-3/4" high
2400 sq.in.
34-3/4" wide
54" high
1296 sq.in.
Minimum Glazing Stop Height 5/8" 5/8"
Minimum Wall Thickness 3-1/2" 3-1/2"

 

Evaluated to the following:

Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UBC-7-2-94, Uniform Building Code;
UL-10(b), Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.

Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.

 

Listing Report Return to Search
Attributes
CriteriaASTM E152-81a
CriteriaUBC 7-2 (1994)
CriteriaUL 10(b) (1997)
CriteriaASTM E163 (1984)
CriteriaUL 9 (2000)
CriteriaUBC 7-4 (1994)
CriteriaNFPA 252 (2003)
CriteriaCAN / ULC S104 (1980) (R1985)
CriteriaNFPA 257 (2003)
CriteriaUL 10(b) 2008 (R2009)
CriteriaCAN / ULC S104 (2010)
CSI Code08 11 00 Metal Doors and Frames
Listing SectionDOOR FRAMES
Listing SectionFIRE WINDOW FRAMES
Spec ID25331