Extruded Aluminum Door Frame, (Fastrak II*) (Knock Down) for installation in 20 minute locations in steel/wood stud Drywall openings.
Limitations: Use with labeled 20 minute Fire Rated, Single Swing, Flush Design Wood Door with wood stiles and rails. Cylindrical and Mortise Latches with 2-3/4 backset. Pemko HSS2000 Intumescent strip must be provided on door frame. (See manufacturer's installation instructions).
| Maximum Overall Dimensions |
39" wide x 108" high |
| Door Openings: |
36" wide x 106-1/2" high |
Testing Standards: UBC 7-2-97/UL-10C (Positive Pressure).
Evaluated to the following
This category includes frames not based on ANSI-A155.1/UL-63 construction Type (such as aluminum, wood, light gauge steel, composite, etc.). These listings will reference specific door types for which each frame is qualified. All frames listed in this section may be used in positive pressure assemblies per the terms and limitations of the individual listing.
All frames in this category are identified by a label or marking bearing the wording, "Listed Fire Door Frame", the Warnock Hersey Certification Mark, "UBC-7-2-97/UL-10C. Frames rated at less than 3 hours will have a time interval noted on the label/marking. See Positive Pressure Section Header for more information.