Intertek Directory of Building Products

Total Door 20-180 Min Steel-Faced Stiffened Core Door Model Stl-180-Stif Company: Total Door II, Inc.

FIRE RESISTANT PRODUCTS & COMPONENTS
CATEGORY A DOORS - FIRE ASSEMBLY - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Steel-Faced (16, 18, 20 gauge) (Stiffened Core Type), Swinging Flush Door installation in 3 hour locations. For use in listed proprietary (3-sided) 16 gauge welded steel frames or as per frame manufacturer's listing(s).
Limitations*: Proprietary Latches & Hinge System/Frame/Surface-Mounted Closers/Concealed Closer Arms/Surface-Mounted Protection Plates/Viewer/Surface-Mounted or Mortised Door Bottoms/Metal Edge or Astragal Not Required/Temperature Rise - Greater than 650°F at 30 minutes. 
Configuration Maximum Size*
Single Swing 4'2-3/16" wide x 9'0" high
Standard Pairs 8'4-3/8" wide x 9'0" high
Double Egress Pairs 8'4-3/8" wide x 9'0" high
 
*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions and limitations.
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2026
Certificate Date of Initial RegistrationSeptember 10, 2018
Certificate NumberWHI18- 29795403
CriteriaUBC 7-2 (1997)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CriteriaUL 10(c) (2009) (R2015)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CSI Code08 11 00 Metal Doors and Frames
CSI Code08 11 13 Hollow Metal Doors and Frames
Fire Resistance20 Min w/Hose Stream PP Cat A Door
Fire Resistance60 Min PP Category A Door
Fire Resistance3 Hour PP Category A Door
Fire Resistance90 Min PP Category A Door
Fire Resistance45 Min PP Category A Door
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID25491
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
Temperature Rise@ 30 Min > 650° F
Design Documents
No Results
Public Documents