Travis Industries - Model: 564 HO GSR2 Direct-Vent Fireplace Company: Travis Industries, Inc.

PRODUCT DESCRIPTION
Product Direct Vent Gas Fireplace Heater
Brand Name Fireplace Xtrordinair
Description The 564 HO GSR2 is a direct vent gas fireplace constructed of sheet steel and is designed in-wall installations.  The unit has a straight top viewing area and can be vented from the top.  The unit has overall dimensions of approximately 36.25” (921 mm) high, 36.25” (921 mm) wide and 18.25” (464 mm) deep.
Models 564 HO GSR2
Model Similarity None
Ratings 120V, 60Hz, 1.5A
35,000 Btu/hr.

APPLIANCE RATINGS
  NATURAL GAS PROPANE
Model 564 HO GSR2
Orifice Size 44 55
Normal Input Rate (Btu/hr) 35,000 35,000
Manifold Pressure at Normal Input Rate (in/wc) 3.5 11
Minimum Input Rate (Btu/hr) 10,400 7,500
Manifold Pressure at Minimum Input Rate (in/wc) 1.6 2.9
Minimum Inlet Pressure (in/wc) 5.5 11

VENTING INFORMATION
VENTING
Vent Type Coaxial
Vent Size 5x8 (horizontal terminations) 4x6 5/8 (verticial terminations)
Max. Vertical Length 40 feet
Min. Vertical Length 10 feet
Max. Horizontal Length 20 feet
Min. Horizontal Length 0
Max. Horizontal Length at Min. Vertical Length 4 feet
Min. Vertical Length at Max. Horizontal Length 8 feet
Max. Number of Elbows 4
 
VENT MANUFACTURERS
Enter Manufacturer Name DuraVent

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
FIREPLACE CLEARANCES
Side (external) 12-in (305mm)
Side (internal) 0.5-in (13mm)
Back 0.5-in (13mm)
Floor 0
Combustible Mantle (above base of fireplace)(10” mantle depth) 47-in (1194mm)
 
VENTING SYSTEM CLEARANCES
Top of Horizontal Vent 3-in (76mm)
Sides and Bottom of Horizontal Vent 1-in (26mm)
Side of Vertical Vent 1-in (26mm)
 
MINIMUM ALCOVE DIMENSIONS
Width 60.25-in (1531mm)
Height 47-in (1194mm)
Depth 10-in (254mm)
Listing Report Return to Search
Attributes
CriteriaCSA 2.17 Ed.4 (2017) (R2022)
CriteriaANSI Z21.88 (2017)
CriteriaCSA 2.33 (2017)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypePropane
Fuel TypeNatural Gas
Listing SectionGAS-FIRED VENTED ROOM HEATERS
Spec ID25738