CEMCO ViperStud(TM) and ViperTrack(TM) Non Load Bearing Steel Studs Company: California Expanded Metal Products Co. - CEMCO

 

 
VIPERSTUD25(TM) 0.0155'' Design Thickness 1 5/8'', 2 1/2'', 3 5/8'', 4'', and 6'' depth non load bearing ASTM A653 SS Grade 50 galvanized steel studs.
 
VIPERSTUD20(TM) 0.0245'' Design Thickness 1 5/8'', 2 1/2'', 3 5/8'', 4'', and 6'' depth non load bearing ASTM A653 SS Grade 45 galvanized steel studs.
 
VIPERTRACK(TM) 0.0155" Design Thickness 1 5/8'', 2 1/2'', 3 5/8'', 4'', or 6'' depth ASTM A653 SS Grade 50 friction fit starter track.
 
 
PRODUCT DESCRIPTION
VIPERSTUD20(TM) and VIPERSTUD25(TM) Non Load Bearing C Shaped Steel Studs: ANSI compliant cold rolled galvanized steel studs.  VIPERSTUD(TM) conform to ICC-ES Acceptance Criteria for Steel Studs, Joists, and Tracks (AC46).
 
VIPERTRACK(TM) Steel Starter: cold rolled galvanized steel starter tracks.  The tracks are 1 1/4’’ leg length and are 1 5/8", 2 ½’’, 3 5/8’’, 4" and 6’’ stud depths to match VIPERSTUD.  VIPERTRACK mechanically anchors to competent substrates at minimum 24'' OC, allowing VIPERSTUD to be erected through friction fitting.   VIPERTRACK conforms to ICC-ES Acceptance Criteria for Steel Studs, Joists, and Tracks (AC46).
 
RATINGS
When tested in accordance with ASTM E119, VIPERSTUD and VIPERTRACK met non load bearing fire resistance ratings as noted below when constructed in accordance with the referenced design listing:
Composite Wall Design No. CEM\WF 60-01 – 1 Hour Non Load Bearing Wall Assembly: a composite wall assembly of VIPERSTUD and VIPERTRACK as detailed in Design Listing CEM/WF 60-01 contained in this listing specification.
 
Composite Wall Design No. CEM\WF 60-02 – 1 Hour Non Load Bearing Wall Assembly: a composite wall assembly of VIPERSTUD and VIPERTRACK as detailed in Design Listing CEM/WF 60-02 contained in this listing specification.
 
Composite Wall Design No. CEM\WF 60-03 – 1 Hour Non Load Bearing Wall Assembly: a composite wall assembly of VIPERSTUD and VIPERTRACK as detailed in Design Listing CEM/WF 60-03 contained in this listing specification.
 
Composite Wall Design No. CEM\WF 60-04 – 1 Hour Non Load Bearing Wall Assembly: a composite wall assembly of VIPERSTUD and VIPERTRACK as detailed in Design Listing CEM/WF 60-04 contained in this listing specification.
  
Composite Wall Design No. CEM\WF 120-01 – 2 Hour Non Load Bearing Wall Assembly: a composite wall assembly of VIPERSTUD and VIPERTRACK as detailed in Design Listing CEM/WF 120-01 contained in this listing specification. 
 
Composite Wall Design No. CEM\WF 120-02 – 2 Hour Non Load Bearing Wall Assembly: a composite wall assembly of VIPERSTUD and VIPERTRACK as detailed in Design Listing CEM/WF 120-02 contained in this listing specification.
 Composite Wall Design No. CEM\WF 120-03 – 2 Hour Non Load Bearing Wall Assembly: a composite wall assembly of VIPERSTUD and VIPERTRACK as detailed in Design Listing CEM/WF 120-03 contained in this listing specification.
Composite Wall Design No. CEM\WF 120-04 – 2 Hour Non Load Bearing Wall Assembly: a composite wall assembly of VIPERSTUD and VIPERTRACK as detailed in Design Listing CEM/WF 120-04 contained in this listing specification.
Listing Report Return to Search
Attributes
CriteriaUL 263 (2003)
CriteriaNFPA 251 (2006)
CriteriaCAN / ULC S101 (2007)
CriteriaASTM E119 (2008a)
CriteriaASTM E119 (2010)
CriteriaUL 263 (2011)
CSI Code09 22 16.13 Non-Structural Metal Stud Framing
Fire Resistance2 Hour
Fire Resistance1 Hour Fire Rating
Listing SectionWALL ASSEMBLIES
Spec ID26028