Intertek Directory of Building Products

JELD-WEN 20 Min Custom Carved Doors (without hose stream) Company: JELD-WEN, Inc.

Custom Carved Doors, for installation in 20 minute locations (without Hose Stream) Single Swing and Standard Pairs.  Single swing only in allowed for Mineral core and Celotex core options only. Ratings per door design. For use in any "Category C - Standard" frame. The doors may also be installed in frames listed to "Category C - Proprietary" in accordance with the door manufacturer's installation instructions.


Limitations: Cylindrical Latches with up to a 2-3/4" backset/Deadbolts/Mortise Lock (exception: mortise lock not allowed for mineral core doors)/Surface Mounted Vertical Rod Fire Exit Hardware/Automatic or Manual Mortised or Surface Mounted Flush Bolts/Surface Mounted Rim Type Fire Exit Hardware/Surface Mounted Door Closer/Surface Mounted or Mortised Door Bottom/Electric Raceway installed below the positive pressure plane (bottom 40" of door)/Edge Guards/Viewers/Protection Plates up to 16" high/Plant-Ons.

Maximum Size

EPS, Honeycomb, or Fiberboard Core:

Swing Maximum Size
Single 3'0" wide x 8'0" high
Pairs 6'0" wide x 8'0" high
Double Egress Not Allowed

Minimum 1-11/16" thick

Mineral Core:

Swing Maximum Size
Single 3'0" wide x 6'8" high
Pairs Not Allowed
Double Egress Not Allowed

Minimum 1-11/16" thick

Rating

20 minute without hose, positive pressure, category B doors listed to the following standards:

UBC 7-2 (1997)
UBC 7-2 (1994)
ASTM E2074 (2004)
NFPA 252 (2008)
UL 10C (2009)

Listing Report Return to Search
Attributes
CriteriaUBC 7-2 (1997)
CriteriaUBC 7-2 (1994)
CriteriaASTM E2074 (2004)
CriteriaNFPA 252 (2008)
CriteriaUL 10(b) 2008 (R2009)
CriteriaUL 10(c) (2009)
CSI Code08 10 00 Doors and Frames
CSI Code08 14 00 Wood Doors
Fire Resistance20 Min w/out Hose Stream PP Cat B Door
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID26152
SwingSingle Swing
SwingStandard Pairs