SCM StileLite 200 Framing Company: Stiles Custom Metal, Inc.
Stiles Custom Metal StileLite 200 glazing framing system. Glazing Size Limitations (each individual panel) Glazing Maximum Allowable Clear View Area (sq. inches) Maximum Clear View Width (inches) Maximum Clear View Height (inches) Minimum Glazing Thickness (inches) Pyrobel 120 4434 100-7/8 49-1/4 2-1/16 Pyrobel 120 EG 3828 88 88 2-1/16 Pyrobel 120 IGU 3828 88 88 2-1/16 Pyrobel 60 4434 94 94 1 Pyrobel 60 EG 4434 94 94 1 Pyrobel 60 IGU 4434 94 94 1 In addition to the above noted glazings, any glazing listed per UL 263, ASTM E119, or CAN/ULC S101 may be installed in framing used as a transparent wall system. Any glazing listed per UL 9, NFPA 257, or NFPA 251 may be installed in sidelight/window installations. Maximum clear view dimensions shall be limited to the glazing specifications.
Glazing Size Limitations (each individual panel) Glazing Maximum Allowable Clear View Area (sq. inches) Maximum Clear View Width (inches) Maximum Clear View Height (inches) Minimum Glazing Thickness (inches) Pyrobel 120 4434 100-7/8 49-1/4 2-1/16 Pyrobel 120 EG 3828 88 88 2-1/16 Pyrobel 120 IGU 3828 88 88 2-1/16 Pyrobel 60 4434 94 94 1 Pyrobel 60 EG 4434 94 94 1 Pyrobel 60 IGU 4434 94 94 1 In addition to the above noted glazings, any glazing listed per UL 263, ASTM E119, or CAN/ULC S101 may be installed in framing used as a transparent wall system. Any glazing listed per UL 9, NFPA 257, or NFPA 251 may be installed in sidelight/window installations. Maximum clear view dimensions shall be limited to the glazing specifications.
The StileLite 200 framing system is listed per the following standards: UL 263 ASTM E119 CAN/ULC S101 NFPA 251 NFPA 257 UL 9 For the following fire resistance ratings: Glazing Rating Pyrobel 120 2 Hours Pyrobel 120 EG 2 Hours Pyrobel 120 IGU 2 Hours Pyrobel 60 1 Hour Pyrobel 60 EG 1 Hour Pyrobel 60 IGU 1 Hour Listed Glazing Per the glazing rating up to 2 hours
UL 263 ASTM E119 CAN/ULC S101 NFPA 251 NFPA 257 UL 9
Glazing Rating Pyrobel 120 2 Hours Pyrobel 120 EG 2 Hours Pyrobel 120 IGU 2 Hours Pyrobel 60 1 Hour Pyrobel 60 EG 1 Hour Pyrobel 60 IGU 1 Hour Listed Glazing Per the glazing rating up to 2 hours