Profiled Core (Proprietary Construction), Fire Door for installation in 20 minute pairs locations (without hose stream) and 20 minute single locations (with hose stream). For use in any "Category C - Standard" frame. The doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions.
Limitations:
Cylindrical Latches with up to a 2-3/4" Backset/Deadbolts/Surface Mounted Vertical Rod Fire Exit Devices/Automatic or Manual Mortised or Surface Flush Bolts/Electric Raceway installation below the positive pressure plane (bottom 40" of door)/Surface Mounted Door Closer/Viewers/Surface Mounted or mortised Door Bottoms/Protection Plates up to 16".
| Door Type |
Maximum Size of Openings |
| Single Swing |
3'0" wide x 8'0" high |
| Pairs |
6'0" wide x 8'0" high (4-point latching or 3-point latching with metal astragal) |
| Double Egress |
6'0" wide x 8'0" high (4-point latching) |
RATINGS
20 Minute fire resistance, without hose, positive pressure to the following standards:
NFPA 252 (2008)
UL 10C (2009)