Intertek Directory of Building Products

Concept Frames 90 Min Hollow Metal Door and Frame Assembly Company: Concept Frames, Inc.

Hollow Metal Type (18, 16, 14 gauge) (Steel-Stiffened), Swinging Flush Design Fire Door and Pressed Steel (Welded-Up) (16, 14, 12 gauge) Door/Frame Assembly for installation in 90 minute locations (per HMMA 861-00).

LISTING LIMITATIONS

DOORS

    • 14,16 or 18 gage face sheets
    • Steel stiffened construction (to the manufacture’s individual listings or HMMA 861)
    • Maximum nominal leaf size – 5’ width and 12’ height
    • 1-3/4” to 2” thickness
    • Maximum fire-protection rating – 1-1/2 hours
    • Single or pair (same direction) configurations
    • Non-temperature rise rated doors (TRR exceeding 650°F at 20 minutes), provided with 2 pcf maximum density batt-type insulation in the voids between stiffeners
    • Maximum temperature rise rating – 450°F at 30 minutes
    • Astragal required for TRR pairs exceeding 8’ in width or 10’ in height
    • For use in welded frame product described below only 

FRAMES

    • 12, 14, or 16 gage welded frames and transom frames
    • Maximum fire-protection rating – 1-1/2 hours
    • Constructed in accordance with the individual manufacturer’s listings or HMMA 861
    • Maximum nominal door width – 5’ singles, 10’ pairs (same direction)
    • Maximum combined  nominal door/transom opening height – 12’
    • Transom opening may be provided with:
      • 1-3/4” thick hollow metal panels constructed as detailed in the individual manufacturer’s listings or utilizing the door  construction indicated above to a maximum height of 4’ or
      • In-fill panels constructed in accordance with UL Subject 63, or
      • Listed glazing materials, within the size, area, and fire-protection rating limitations of the glazing material to be  installed
    • Jamb, head, and mullion profiles in accordance with UL Subject 63
    • Welded anchorage to suit wall conditions, for masonry, stud and existing masonry/concrete partitions, in accordance  with the individual manufacturer’s listings, HMMA 850 or 861
    • Installation in accordance with the recommended installation practices presented in NFPA 80, “Fire Doors and Windows”, NAAMM/HMMA 840, “Guide Specifications for Installation of Hollow Metal Doors and Frames”, and NAAMM/HMMA850, “Fire-Rated Hollow Metal Doors and Frames”
    • Splices may be provided in jambs, heads, and mullions for field welding
Listing Report Return to Search
Attributes
CriteriaUL 10(c) (1998)
CriteriaUBC 7-2 (1997)
CriteriaNFPA 252 (1999)
CriteriaCAN4 S106 (1985)
CriteriaCAN4 S104 (1985)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CSI Code08 11 00 Metal Doors and Frames
CSI Code08 11 13 Hollow Metal Doors and Frames
Fire Resistance90 Min Positive Pressure
Frame OptionsHollow Metal
Listing SectionDOOR FRAMES
Spec ID26831
SwingSingle Swing
SwingStandard Pairs
Temperature Rise@ 30 Min = 450° F MAX Where Lites Do Not Exceed 100 IN2