Intertek Directory of Building Products

JELD-WEN 20 Min Molded Simulated Panel Door (without hose stream) Company: JELD-WEN, Inc.

CATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED

Simulated Panel Type (Proprietary Construction), Fire Door for installation in 20 minute locations (without hose stream). For use in any "Category C - Standard" frame. The doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions.

Limitations

Mortise Latches/Cylindrical Latches with up to a 2-3/4" Backset/Deadbolts/Surface Mounted or Mortised Rim Type Fire Exit Devices/ Surface Mounted Vertical Rod Fire Exit Devices/Automatic or Manual Mortised or Surface Flush Bolts/ Viewers/Electric Raceway installed below the positive pressure plane (bottom 40" of door)/Surface Mounted Door Closer/Surface Mounted or Mortised Door Bottoms/Protection Plates up to 16".

 

Maximum Size of Openings

Single Swing

3’0” wide x 8’0” high. 

Standard Pair

6’0” wide x 8’0” high.

Double Egress Pair

6'0" wide x 8'0" high.

 Testing Standards

UBC-7-2-97/UL-10C (Positive Pressure).

Evaluated to the following...

This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.

 

These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.

 

All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.

 

All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL-10C".

 

Listing Report Return to Search
Attributes
CriteriaNFPA 252 (2008)
CriteriaUL 10(b) 2008 (R2009)
CriteriaUL 10(c) (2009)
CriteriaNFPA 252 (2012)
CSI Code08 10 00 Doors and Frames
Fire Resistance20 Min w/out Hose Stream NP
Fire Resistance20 Min w/out Hose Positive Pressure
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID27013
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
Design Documents
No Results
Public Documents