Ceco Volume IV - Fire Door Frame Specs Company: Ceco Door Products
Pressed Steel Door Frame (14, 16 or 18 gauge) (DS/S Series*) (Knock-Down) for installation in 1-1/2 hour steel/wood stud drywall openings
Pressed Steel Door Frame (12, 14, 16 or 18 gauge) (S/C Series*) (Knock-Down or Welded Up) for installation in 3 hour steel/wood stud drywall or masonry openings.
Fabrication Standard: 3821 Pressed Steel Door Frame (18 gauge Base Frame & 22 gauge Trim) (SR Series*) (Knock-Down) for installation in 1-1/2 hour steel/wood stud drywall openings.
Fabrication Standard: 3821
Pressed Steel Side Light Door Frame (14 or 16 gauge) (Welded Up) for installation in 20 minute locations (tested without hose stream) in steel/wood stud drywall or masonry openings.
Pressed Steel Side Light Door Frame (14 or 16 gauge) (Welded Up) for installation in 1 hour locations in steel/wood stud drywall or masonry openings. Limitations: "Firelight" listed glazing (or equivalent) must be used, and prior approval must be obtained from the authority having jurisdiction, as applicable code requirements may vary. All the listing conditions for the glazing must be satisfied.
Limitations: "Firelight" listed glazing (or equivalent) must be used, and prior approval must be obtained from the authority having jurisdiction, as applicable code requirements may vary. All the listing conditions for the glazing must be satisfied.
Pressed Steel Side Light Door Frame (14 or 12 gauge) (Welded Sections or Fully Welded) for installation in 45 minute locations in steel/wood stud drywall or masonry openings. Limitations: Side Lights require Velga Contraflam CF-45* Intertek labeled glazing per O'Keeffe's, Inc. glazing installation instructions.
Limitations: Side Lights require Velga Contraflam CF-45* Intertek labeled glazing per O'Keeffe's, Inc. glazing installation instructions.
Pressed Steel Door Frame (14 gauge base frame & 16 gauge trim) (Retro-Tech AF Series*) (Knock-Down or Welded Up) for installation in 1-1/2 hour steel/wood stud drywall or masonry openings. Limitations: Some designs are not approved for 1-1/2 hour rating or maximum sizes shown
Limitations: Some designs are not approved for 1-1/2 hour rating or maximum sizes shown
Pressed Steel Side Light Door Frame (14 or 16 gauge) (Welded Up) for installation in 45 minute locations in steel/wood stud drywall or masonry openings.
Pressed Steel Door Frame with Transom and/or Side Light (14, 16 gauge) (Welded Up) for installation in up to 1-1/2 hour locations in steel/wood stud drywall or masonry openings. Limitations: "PyroStop" listed glazing must be used. Prior approval must be obtained from the Authority Having Jurisdiction as applicable code requirements may vary. All listings conditions for the glazing must be satisfied.
Limitations: "PyroStop" listed glazing must be used. Prior approval must be obtained from the Authority Having Jurisdiction as applicable code requirements may vary. All listings conditions for the glazing must be satisfied.
*Manufacturer's Designation Note: For additional information please refer to Openings listings.
Evaluated to the following... Unless otherwise noted, assemblies in this section have been tested to the following standards: NFPA-252, Standard Methods of Fire Tests of Door Assemblies; UL-10(b), Fire Tests of Door Assemblies; and are installed, unless otherwise noted, in accordance with the following: NFPA-80, Fire Doors & Windows. Manufacturer's Instructions. Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements. All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.
Unless otherwise noted, assemblies in this section have been tested to the following standards: NFPA-252, Standard Methods of Fire Tests of Door Assemblies; UL-10(b), Fire Tests of Door Assemblies; and are installed, unless otherwise noted, in accordance with the following: NFPA-80, Fire Doors & Windows. Manufacturer's Instructions. Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements. All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.
NFPA-252, Standard Methods of Fire Tests of Door Assemblies; UL-10(b), Fire Tests of Door Assemblies;
NFPA-80, Fire Doors & Windows. Manufacturer's Instructions.
Pressed Steel Fire Window Frame (14, 16 gauge) (Knock-Down or Welded Up) for installation in 3/4 hour locations in steel/wood stud drywall or masonry openings.
Pressed Steel Fire Window Frame (14, 16 gauge) (Knock-Down or Welded Up) for installation in 20 minute locations (tested without hose stream) in steel/wood stud drywall or masonry openings.
Pressed Steel Fire Window Frame (14, 16 gauge) (Welded Up) for installation in 1 hour locations in steel/wood stud drywall or masonry openings. Limitations: "Firelite" listed glazing or equivalent must be used. Prior approval must be obtained from the Authority Having Jurisdiction as applicable code requirements may vary. All the listing conditions for the glazing must be satisfied.
Limitations: "Firelite" listed glazing or equivalent must be used. Prior approval must be obtained from the Authority Having Jurisdiction as applicable code requirements may vary. All the listing conditions for the glazing must be satisfied.
Note: Refer to 'Limitations' of the listed glazing. Stop Height: 5/8" Pressed Steel Fire Window Frame (14, 12 gauge) (Fully Welded) for installation in 3/4 hour locations in steel/wood stud drywall or masonry openings. Limitations: Lights require Vegla Contraflam CF-45* ITS labeled glazing per O'Keeffe's, Inc. glazing installation instructions.
Note: Refer to 'Limitations' of the listed glazing. Stop Height: 5/8"
Limitations: Lights require Vegla Contraflam CF-45* ITS labeled glazing per O'Keeffe's, Inc. glazing installation instructions.
*Manufacturer's Designation Evaluated to the following... Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards: UL-9, Fire Tests of Window Assemblies. and are installed, unless otherwise noted, in accordance with the following: NFPA-80, Fire Doors & Windows. Manufacturer's Instructions. Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements. All assemblies are identified by a label or marking bearing the wording "Listed Fire Window Frame", a time interval, a serial number and the WHI Certification Mark.
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards: UL-9, Fire Tests of Window Assemblies. and are installed, unless otherwise noted, in accordance with the following: NFPA-80, Fire Doors & Windows. Manufacturer's Instructions. Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements. All assemblies are identified by a label or marking bearing the wording "Listed Fire Window Frame", a time interval, a serial number and the WHI Certification Mark.
UL-9, Fire Tests of Window Assemblies.
Pressed Steel Transom and/or Side Light Door Frame Assembly (14, 16 gauge) for installation in up to 45 minute locations in steel/wood stud drywall or masonry openings. Glazing Types: Listed 1/4" wired glass or FireLite®.
Pressed Steel Fire Window Frame (14, 16 gauge) for installation in up to 45 minute locations in steel/wood stud drywall or masonry openings. Glazing Types: Listed 1/4" wired glass or FireLite®.
Pressed Steel Frame (14, 16 gauge) for installation in up to 90 minute locations in steel/wood stud drywall or masonry opening.
Pressed Steel Frame (14, 16 gauge) (Adjustable) for installation in up to 90 minute locations in steel/wood stud drywall or masonry opening.