Intertek Directory of Building Products

Jotul Model GF 300 BV and GF 300 BV MV Vented Gas Fireplace Heater Company: Jøtul North America, Inc.

PRODUCT DESCRIPTION
Product Direct Vent Gas Fireplace
Brand Name Jotul
Description The model GF 300 BV and GF300 BV MV vented gas fireplace heaters are freestanding space heaters.  It is equipped and operated with a piezo/standing pilot ignition system.  The unit front contains a glass panel for viewing the flame and simulated wood logs.  The minimum shutter settings are 1/8-in for NG and LPG.
Models GF300 BV and GF300 BV MV
Model Similarity The models GF300 BV and GF300 BV MV are identical with the only difference being that the GF300 BV MV uses a pilot on demand control valve that turns off the pilot burner after 7 days of uninterrupted use.
Ratings 120V, 1.5A, 60 Hz, 50W (Blower)

APPLIANCE RATINGS
  NATURAL GAS PROPANE
Model GF300 BV
Orifice Size (0-2000 ft) #39 #53
Orifice Size (2000-4500 ft) #40 #53
Normal Input Rate (Btu/hr)(0-2000-ft) 26,000 26,000
Normal Input Rate (Btu/hr)(2000-4500-ft) 25,800 26,000
Manifold Pressure at Normal Input Rate (in.wc/kPa) 3.8/0.95 11.0/2.74
Minimum Input Rate (Btu/hr) 15,000 15,000
Manifold Pressure at Minimum Input Rate (in.wc/kPa) 1.2/0.30 2.9/0.72
Minimum Inlet Pressure (in.wc/kPa) 5.0/1.24 12.0/2.99

VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 35 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
VENTING
Vent Type B-Vent
Vent Size 4”
Max. Vertical Length 35-feet
Min. Vertical Length 7-feet
Max. Horizontal Length 4-feet
Max. Number of Elbows 3-90°

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES
Rear (in/mm) 2/51
Sidewall (in/mm) 3/76
Corner (in/mm) 3/76
Ceiling (in/mm) (from unit top) 32.25/819
Mantle (in/mm) (11.5” depth) 56.75/1441
 
VENTING SYSTEM CLEARANCES
Top of Horizontal Vent (in/mm) 2/51
Sides and Bottom of Horizontal Vent (in/mm) 2/51
Side of Vertical Vent (in/mm) 1/25
 
MINIMUM ALCOVE DIMENSIONS
Width (in/mm) 36/914
Height (in/mm) 61/1550
Depth (in/mm) 24/610
Listing Report Return to Search
Attributes
CriteriaCSA 2.17 Ed.4 (2017) (R2022)
CriteriaANSI Z21.88 / CSA 2.33 (2019) (R2024)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypePropane
Fuel TypeNatural Gas
Listing SectionVENTED GAS FIREPLACE HEATERS
Listing SectionGAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES
Spec ID27352
Design Documents
No Results
Public Documents
No Results