Intertek Directory of Building Products

Trussbilt 20-45 Min Fire Rated Window Frames Company: Trussbilt, LLC

Pressed Steel Fire Window Frame (16, 14, 12 gauge) (Knock-Down or Welded Up) for installation singly or pairs (including Double Egress) in 20 or 45 minute locations in steel/wood stud drywall or masonry openings.
Limitations
Visible Area
Groove Depth
300 sq.in. 1/2"
400 sq.in. 9/16"
500 sq.in. 5/8"
600 sq.in. 11/16"
1296 sq.in. 3/4"
Maximum Overall Dimensions: 7'0" wide x 10'0" high
Visible Glazing (each light) 1296 sq.in.
Maximum Width or Height (each light) 54"
Maximum Throat Opening: 4" Min. and 12-3/4" Max.
 
Evaluated to the following...
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E163, Methods of Fire Tests of Fire Window Assemblies.
CAN4-S106, Standard Method for Fire Tests of Window & Glass Block Assemblies.
NFPA-257, Standard Method for Fire Tests of Fire Window Assemblies.
UBC-7-4-94, Uniform Building Code.
UL-9, Fire Tests of Window Assemblies.
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
 
All assemblies are identified by a label or marking bearing the wording "Listed Fire Window Frame", a time interval, a serial number and the WHI Certification Mark.
Listing Report Return to Search
Attributes
CriteriaCAN4 S106 (1985)
CriteriaNFPA 257 (2007)
CriteriaUL 9 (2009)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min w/out Hose Stream PP Cat A Door
Fire Resistance45 Min Neutral Pressure
Listing SectionFIRE WINDOW FRAMES
Spec ID27586