Fire Tape is a multi-layered tape used to cover and seal joints of gypsum board panels. Fire Tape combines the attributes of paper tape and fiberglass tape into one single product. Fire Tape is an alternative to conventional paper and fiberglass tape used as a finishing component for gypsum board assemblies.
FIRE RATINGS
| Test Standard |
Rating |
Design Number |
| ASTM E119, CAN/ULC S101, UL263, NFPA 251 |
1-hr |
EZT/FC 60-01
EZT/FC 60-02
EZT/FC 60-03
EZT/FC 60-04
EZT/FC 60-05
EZT/FC 60-06
EZT/FC 60-07
EZT/FC 60-08
EZT/RC 60-01
EZT/RC 60-02
EZT/RC 60-03
EZT/WA 60-01
EZT/WA 60-02
EZT/WA 60-03
EZT/WA 60-04 |
| ASTM E119, CAN/ULC S101, UL263, NFPA 251 |
1 ½ - hr |
EZT/FC 90-01
EZT/FC 90-02
EZT/FC 90-03
EZT/FC 90-04
EZT/FC 90-05
EZT/FC 90-06
EZT/FC 90-07
EZT/FC 90-08
EZT/RC 90-01
EZT/RC 90-02
EZT/RC 90-03 |
| ASTM E119, CAN/ULC S101, UL263, NFPA 251 |
2-hr |
EZT/FC 120-01
EZT/FC 120-02
EZT/FC 120-03
EZT/FC 120-04
EZT/FC 120-05
EZT/FC 120-06
EZT/FC 120-07
EZT/FC 120-08
EZT/RC 120-01
EZT/RC 120-02
EZT/RC 120-03
EZT/WA 120-01
EZT/WA 120-02
EZT/WA 120-03
EZT/WA 120-04 |
Designs listed are minimum construction requirements to achieve fire rating.
Unless otherwise noted, fire ratings apply to tests conducted on both sides.
MATERIAL RATINGS
| Test Standard |
Test Type |
Rating |
| ASTM C474/C475 |
Thickness |
< 0.012-in. |
| Width |
Min. 1 7/8-in, Max. 2 ¼-in., + 1/32-in. |
| Strength |
53.4 lbs/in. of width |
| Dimensional Stability Length-wise |
< 0.40% |
| Dimensional Stability Cross-wise |
< 2.50% |
| ASTM C474/C475/D3330 |
Adhesion |
Complies |
| Durability |
Complies |