Panel Type (Proprietary Construction) Swinging Wood Fire Door for installation singly or in pairs for 20 minute locations (without hose stream).
Limitations: Cylindrical or Mortise Latches with minimum 1/2" Bolt Throw and up to 2-3/4" Backset/Surface Mounted Bolts/Automatic Drop Seal/Viewer. Must be installed in 16 gauge or heavier steel frame.
Configuration |
Maximum Size |
Single |
4'0" wide x 8'0" high |
Standard Pairs |
8'0" wide x 8'0" high |
Panel Type (Proprietary Construction) Wood Fire Door for installation singly in 20 minute locations in any "Category C - Standard" Frame.
Limitations: Cylindrical or Mortise Latches with minimum 1/2" Bolt Throw and 2-3/4" Backset/Surface-Mounted Vertical Rods Fire Exit Hardware/Surface-Mounted Rim-Type Fire Exit Hardware/Surface-Mounted Bolts/Surface-Mounted Closer/Viewer/Kickplates/Door Bottoms.
Configuration |
Maximum Size |
Single Swing |
3'6" wide x 8'0" high |
Standard Pairs |
NA |
Panel Type (Proprietary Construction) Wood Fire Door for installation singly or standard pairs in 20 minute locations in any "Category C-Standard" Frame.
Limitations: Cylindrical or Mortise Latches with minimum 1/2" Bolt Throw and 2-3/4" Backset/Surface-Mounted Vertical Rods Fire Exit Hardware/Surface-Mounted Rim-Type Fire Exit Hardware/Surface-Mounted Bolts/Surface-Mounted Closer/Doors without Hose Stream.
Configuration |
Maximum Size |
Single Swing |
3'6" wide x 8'0" high |
Standard Pairs |
8'0" wide x 8'0" high |
Panel Type (Proprietary Construction) Wood Fire Door for installation singly in 60 minute locations in any "Category C - Standard" frame.
Limitations: Cylindrical or Mortise Latches with minimum 1/2" Bolt Throw and 2-3/4" Backset/Surface-Mounted Vertical Rods Fire Exit Hardware/Surface-Mounted Rim-Type Fire Exit Hardware/Surface-Mounted Bolts/Surface-Mounted Closer/Viewer/Kickplates/Door Bottoms.
Configuration |
Maximum Size |
Single Swing |
3'6" wide x 8'0" high |
Standard Pairs |
NA |
Testing Standard: UBC-7-2-97/UL-10C (Positive Pressure).