Vancouver Door Category B - Doors 45-90 Min Company: Vancouver Door LLC

Mineral Core Type (Wood Faced), Swinging flush design fire door of 90 minute door construction for installation singly or in pairs in 45 minute locations using a field applied edge-sealing system. For use in any "Category C - Standard" frame. Also may be used in any Steel frame listed in "Category C - Proprietary" in accordance with the door manufacturer's installation instructions. Please refer to the door manufacturer's installation instructions for edge-seal system requirements.

Limitations: Cylindrical/Mortise Latches with minimum 1/2" bolt throw and up to 5" Backset/Deadbolts/Surface Mounted Vertical Rod Fire Exit Hardware Mortise/Rim Type Fire Exit Hardware/Automatic/Manual Flush Bolts/Surface Bolts/Vision Panels up to 100 sq.in. using Intumescent Strips/Plates up to 48". 4-Point Latching Required for Pairs. See Manufacturer's installation instructions.

Configuration Maximum Size
Single Swing 4'0" wide x 9'0" high
4'0" wide x 8'0" high
Standard Pairs 8'0" wide x 8'0" high

*See manufacturer's installation instructions for additional information, restrictions and limitations.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).
Listing Report Return to Search
Attributes
CriteriaUBC 7-2 (1997)
CriteriaUL 10(c) (2009)
CSI Code08 14 00 Wood Doors
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID27962
Design Documents
No Results
Public Documents
No Results