Intertek Directory of Building Products

3M Fire Protection GIS / GIS+ Company: 3M Company

CATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Wood Core Type (Particleboard, Stave Core), Swinging flush door for installation in up to 20 minute (without hose stream) locations. For use in listed (3 sided) 16 gauge welded steel frames meeting ANSI-A155.1/UL-63 or as per frame manufacturer's listing(s). Additional edge-sealing system required - see table below & edge-seal system manufacturer's listing.
Limitations*: Mortise or Cylindrical Latches with maximum 5" backset/Mortise Exit Devices/Surface Mounted Vertical Rod Fire Exit Devices/Rim Type Fire Exit Devices/Deadbolts/Surface Bolts/Automatic Flush Bolts/Surface Mounted Closers/Surface Mounted Protection Plates/Plant-Ons/Viewer/Electric Raceway/Vision Light Kit - Maximum 1200 sq.in./Surface Mounted Door Bottoms/Astragal Required.
 
Configurations Max. Size Edge-Sealing
System(s)
Single Swing 4'0" wide x 8'0" high 3M GIS/GIS+
Standard Pairs 8'0" wide x 8'0" high 3m GIS/GIS+
Double Egress Pairs N/A N/A
 
Wood Core Type (Particleboard, Stave Core), Swinging flush door for installation in up to 20 minute (without hose stream) locations. For use in listed (3 sided) Raco Trimstyle frame. Additional edge-sealing system required - see table below & edge-seal system manufacturer's listing.
Limitations*: Mortise or Cylindrical Latches with maximum 5" backset/Mortise Exit Devices/Surface Mounted Vertical Rod Fire Exit Devices/Rim Type Fire Exit Devices/Deadbolts/Surface Mounted Closers/Surface Mounted Protection Plates/Plant-Ons/Viewer/Electric Raceway/Vision Light Kit - Maximum 1200 sq.in./Surface Mounted Door Bottoms.
 
Configurations Max. Size Edge-Sealing
System(s)
Single Swing 4'0" wide x 10'0" high 3M GIS/GIS+
Standard Pairs N/A N/A
Double Egress Pairs N/A N/A
 
Wood Core Type, Swinging flush door for installation in up to 45 minute locations. For use in listed (3 sided) 16 gauge welded steel frames meeting ANSI-A155.1/UL-63 or as per frame manufacturer's listing(s). Additional edge-sealing system required - see table below & edge-seal system manufacturer's listing.
Limitations*: Mortise or Cylindrical Latches with maximum 5" backset/Mortise Exit Devices/Surface Mounted Vertical Rod Fire Exit Devices/Rim Type Fire Exit Devices/Deadbolts/Surface Bolts/Automatic Flush Bolts/Surface Mounted Closers/Surface Mounted Protection Plates/Viewer/Electric Raceway/Vision Light Kit - Maximum 1296 sq.in./Surface Mounted Door Bottoms/Astragal Required/Temperature Rise - 250°F at 30 minutes.
 
Configurations Max. Size Edge-Sealing
System(s)
Single Swing 4'0" wide x 8'0" high 3M GIS/GIS+
Standard Pairs 8'0" wide x 8'0" high 3m GIS/GIS+
Double Egress Pairs N/A N/A
 
*See manufacturer's installation instructions for additional information on Smoke & Draft Control, size restrictions, and limitations.
Testing Standard: UBC-7-2-97/UL-10C (Positive Pressure).
Evaluated to the following:
This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.
These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL-10C". See Positive Pressure Section Header for more information.
CATEGORY F - LIGHT KITS
Graphite Instumescent Seal (GIS) Intumescent Material for installation on Listed Wood Lite bend in Single Swing Wood Doors. Refer to Smoke Control Door Assemblies for Smoke and Draft Control Listing.
 
Model No Maximum Door Type Glazing Rating
Area Width Height
Listed Bead Wood 1296 24" 54" Wood FR Wired 20 Minute
 
*See manufacturer's installation instructions for additional information, restricts and limitations.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).

Evaluated to the following:
Products listed in this category have been evaluated for use in positive pressure fire door assemblies for specific types of doors and with specific glazing systems. Refer to the individual listings for limitations and requirements.
Note: Glass and glazing material used in these assemblies do not require a positive pressure marking but must be marked as fire rated.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements. All assemblies are identified by a label or marking bearing the Warnock Hersey Certification Mark. See Positive Pressure Section Header for more information. 
CATEGORY G - EDGE SEALING SYSTEMS
Graphite Intumescent Seal (GIS and GIS+), Intemescent Material for installation on Listed Steel and Wood Frames and proprietary aluminum fram with listed Single Swing Wood Doors. Surface applied with self-stick tape to head and jambs (see manufacturer's instructions).
 
Model Door Frame* Configuration Rating Max Size
GIS Wood Wood Single Swing 20 Min 4'0"w x 8'0"h
GIS Wood 18-16 ga. Steel Pairs 20 Min 8'0"w x 8'0"h
GIS Wood Raco Trimstyle Single Swing 20 Min 4'0"w x 10'0"h
GIS Wood 18-16 ga. Steel Single Swing 45 Min 4'0"w x 8'0"h
GIS Wood 18-16 ga. Steel Pairs 45 Min 8'0"w x 8'0"h
 
*See manufacturer's installation instructions for additional information, restriction and limitations.
Refer to Category H: "Smoke and Draft Control Gasketing"
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).

Evaluated to the following:
This category includes field-applied systems only. Category G - Edge-Seal Systems are for use in Category B doors, or meeting edges (only) of Category A doors. These systems are surface-applied to either the perimeter of the door or frame, or meeting edge of the door. They may be kerf-applied, adhesive-backed, or mechanically fastened.
Edge-sealing systems are identified by a label or marking bearing the Warnock Hersey Certification Mark. See Positive Pressure Section Header for more information.
CATERGORY H - SMOKE & DRAFT CONTROL GASKETING
Graphite Intumescent Seal (GIS and GIS+), Intuemscent Material for installation on Listed Steel and Wood Frames and proprietary aluminum frame with listed Single Swing Wood Doors. Surface applied with self-stick tape to head and jambs (see manufacturer's instructions).
 
Model Door Frame* Configuration Rating Max Size
GIS Wood Wood Single Swing 20 Min 4'0"w x 8'0"h
GIS Wood 18-16 ga. Steel Pairs 20 Min 8'0"w x 8'0"h
GIS Wood Raco Trimstyle Single Swing 20 Min 4'0"w x 10'0"h
GIS Wood 18-16 ga. Steel Single Swing 45 Min 4'0"w x 8'0"h
GIS Wood 18-16 ga. Steel Pairs 45 Min 8'0"w x 8'0"h
*See manufacturer's installation instructions for additional information, restriction and limitations.
Refer to Category H: "Smoke and Draft Control Gasketing"
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).

Evaluated to the Following:
This category includes gasket systems that are surface-applied (such as kerf-applied, adhesive-backed, or mechanically-attached) to frames or doors. It includes gasketing for the meeting edges for use in pair and double egress assemblies.
Note: This category covers gasket systems that have been evaluated for use in positive pressure rated assemblies, but do not provide an edge-sealing system to the opening (see Category G). These gasket systems have been evaluated in accordance with UBC-7-2-97, Parts I and II.
All smoke & draft control gasketing systems are identified by a label or marking bearing the Warnock Hersey Certification Mark. See Positive Pressure Section Header for more information.


Certified Products can be identified by the Omega Point Laboratories (OPL), Warnock Hersey (WH), or ETL Certification Mark
 
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2025
Certificate Date of Initial RegistrationJuly 3, 2017
Certificate NumberWHI17–20265308
CriteriaUBC 7-2 (1997)
CriteriaUL 10(c) (2009)
CSI Code07 80 00 Fire and Smoke Protection
Listing SectionCATEGORY G - EDGE-SEALING SYSTEMS
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Listing SectionCATEGORY H - SMOKE & DRAFT CONTROL GASKETING
Listing SectionCATEGORY F - LIGHT KITS
Spec ID28148
Design Documents
No Results
Public Documents
No Results