Touch N' Seal Class I FR Spray Foam System (HFC)
Touch N' Seal (TNS) Class I FR Spray Foam System/Touch N' Foam Professional (TNF PRO) Class I FR Spray Foam System/Touch N’ Seal HVAC 1.75 Spray Foam System (HFC), including following packaging size, is a two component, closed cell, medium density spray-applied foam insulation used in open wall cavities, attics and crawl spaces.
- Touch N’ Foam® Pro System 200
- Touch N’ Seal® System 200
|
- Touch N’ Foam® Pro System 600
- Touch N’ Seal® System 600
|
- Touch N’ Foam Pro® Constant Pressure Foam System CPDS-750FR
- Touch N’ Seal® Constant Pressure Foam System CPDS-750FR
|
- Touch N’ Seal® Refillable RF-17-ICC
|
- Touch N’ Seal® Refillable RF-60-ICC
|
- Touch N’ Seal® Refillable RF-120-ICC
|
Touch N' Seal Class I FR Spray Foam System (Low GWP)
Touch N' Seal (TNS) Class I FR Spray Foam System/Touch N' Foam Professional (TNF PRO) Class I FR Spray Foam System/Touch N’ Seal HVAC 1.75 Spray Foam System (Low GWP), including following packaging size, is a two component, closed cell, medium density spray-applied foam insulation used in open wall cavities, attics and crawl spaces.
- Touch N’ Foam® Pro System 200 (Low GWP)
- Touch N’ Seal® System 200 (Low GWP)
|
- Touch N’ Foam® Pro System 600 (Low GWP)
- Touch N’ Seal® System 600 (Low GWP)
|
- Touch N’ Foam Pro® Constant Pressure Foam System CPDS-750FR (Low GWP)
- Touch N’ Seal® Constant Pressure Foam System CPDS-750FR (Low GWP)
|
- Touch N’ Seal® Refillable RF-17-ICC (Low GWP)
|
- Touch N’ Seal® Refillable RF-60-ICC (Low GWP)
|
- Touch N’ Seal® Refillable RF-120-ICC (Low GWP)
|
HFC Ratings:
Test Standard |
Result(s) |
ASTM E84 – 2 in. nominal thickness |
Flame Spread: ≤25
Smoke Development: ≤450 |
ASTM E283 – 1 in. nominal thickness |
0.002 L/s/m2 |
ASTM C518 – R-Value |
1 in. nominal thickness: 5.1
3 in. nominal thickness: 15.07 |
HFO Ratings:
Test Standard |
Result(s) |
ASTM E84 – 1.5 in. nominal thickness |
Flame Spread: ≤25
Smoke Development: ≤450 |