Intertek Directory of Building Products

DAP Global Inc. - Touch N' Seal Class I FR Spray Foam System/Touch N' Foam Professional Class I FR Spray Foam System Company: DAP Global Inc.

Touch N' Seal Class I FR Spray Foam System (HFC)
Touch N' Seal (TNS) Class I FR Spray Foam System/Touch N' Foam Professional (TNF PRO) Class I FR Spray Foam System/Touch N’ Seal HVAC 1.75 Spray Foam System (HFC), including following packaging size, is a two component, closed cell, medium density spray-applied foam insulation used in open wall cavities, attics and crawl spaces.
  • Touch N’ Foam® Pro System 200
  • Touch N’ Seal® System 200
  • Touch N’ Foam® Pro System 600
  • Touch N’ Seal® System 600
  • Touch N’ Foam Pro® Constant Pressure Foam System CPDS-750FR
  • Touch N’ Seal® Constant Pressure Foam System CPDS-750FR
  • Touch N’ Seal® Refillable RF-17-ICC
  • Touch N’ Seal® Refillable RF-60-ICC
  • Touch N’ Seal® Refillable RF-120-ICC

Touch N' Seal Class I FR Spray Foam System (Low GWP)
Touch N' Seal (TNS) Class I FR Spray Foam System/Touch N' Foam Professional (TNF PRO) Class I FR Spray Foam System/Touch N’ Seal HVAC 1.75 Spray Foam System (Low GWP), including following packaging size, is a two component, closed cell, medium density spray-applied foam insulation used in open wall cavities, attics and crawl spaces.
  • Touch N’ Foam® Pro System 200 (Low GWP)
  • Touch N’ Seal® System 200 (Low GWP)
  • Touch N’ Foam® Pro System 600 (Low GWP)
  • Touch N’ Seal® System 600 (Low GWP)
  • Touch N’ Foam Pro® Constant Pressure Foam System CPDS-750FR (Low GWP)
  • Touch N’ Seal® Constant Pressure Foam System CPDS-750FR (Low GWP)
  • Touch N’ Seal® Refillable RF-17-ICC (Low GWP)
  • Touch N’ Seal® Refillable RF-60-ICC (Low GWP)
  • Touch N’ Seal® Refillable RF-120-ICC (Low GWP)

HFC Ratings:
Test Standard Result(s)
ASTM E84 – 2 in. nominal thickness Flame Spread: 25
Smoke Development: 450
ASTM E283 – 1 in. nominal thickness 0.002 L/s/m2
ASTM C518 – R-Value 1 in. nominal thickness: 5.1
3 in. nominal thickness: 15.07

HFO Ratings:
Test Standard Result(s)
ASTM E84 – 1.5 in. nominal thickness Flame Spread: ≤25
Smoke Development: ≤450
Listing Report Return to Search
Attributes
CriteriaASTM E283 (2004)
CriteriaASTM C518 (2004)
CriteriaASTM D1622 (2003)
CriteriaASTM D1621 (2000)
CriteriaASTM D1622 (2008)
CriteriaASTM D1623 (2009)
CriteriaASTM E84 (2019a)
CriteriaASTM D2126 (1998)
CriteriaASTM E84 (2012)
CriteriaASTM E84 (2011c)
CriteriaASTM E84 (2011b)
CriteriaASTM E84-18a
CriteriaASTM C518 (2017)
CriteriaASTM D2126 (2009)
CriteriaASTM E84 (2010b)
CriteriaASTM D1621 (2010)
CriteriaASTM C518 (2010)
CriteriaASTM E84 (2011a)
CriteriaASTM D1623-78 (1995)
CSI Code07 21 00 Thermal Insulation
Listing SectionBUILDING MATERIALS WITH SURFACE BURNING CHARACTERISTICS
Listing SectionOTHER PRODUCTS
Spec ID28293
Design Documents
No Results
Public Documents
No Results